beautypg.com

Block diagram, Technical data – REMKO PG 25 User Manual

Page 9

background image

9

Block diagram

MV = Electric solenoid

M = Fan motor

STB = Safety thermostat

KL = Terminal strip

S = Operating switch

Note!

Any mode of operation other than specified in these operating instructions is not permissible!

Failing to observe it causes the customer to lose all rights to guarantee or damage claims.

A prerequisite for any material guarantee claims is that the orderer or the orderer’s customer filled

out a „guarantee certification” at the time of the purchase and start-up and returned it to

REMKO GmbH & Co KG. Guarantee certificates are enclosed with every REMKO-heater.

Technical data:

Series PG 25 PG 50

Nominal heat output kW 25 50
Heating capacity kW 10 – 25 25 – 50
Air output m³/h 800 1.450

Fuel/type of gas liquified gas Kat.

I

3 B/P

,

I

3+

Gas pressure bar 1,5 1,5
Gas consuption kg/h 0,78 – 1,95 1,95 – 3,95
Electrical connection 1~ V 230 230
Frequency Hz 50 50
Power consumption kW 0,07 0,11
Fuse-protection (required) A 10 10
Kind of protection IP 44 IP 44

Sound pressure level L

pA

1m

1)

dB(A) 56 – 69 62 – 72

Weight (without accessories) kg 12 20
Dimensions Length mm 450 650
Width mm 260 320
Hight mm 410 510

1) Noise measuring DIN 45635 - 01- KL 3

L1

N

1

2

3

5

4

1

2

3

6

KL

S

MV

STB

M

1~

230V/1~ 50Hz

PE

N

L1

A3

A2

A1

B6

B5

B4

We reserve the right to make modifications in dimensions and
construction in the interests of technical progress.