beautypg.com

Starting, Shut-down – REMKO PG 25 User Manual

Page 6

background image

6

Starting


A properly trained person is to be charged with the
operation of the units, as well as with the control of the
holders and the cylinder stock.

The operator's attention is to be drawn to any
dangers in connection with the use of liquid gas.

Put the operating switch into "0" posi-
tion (= Off) and plug the mains into
an appropriate mains socket
(230V/ 1~ 50 Hz).

The electric connection of the units is to be car-
ried out according to the VDE 0100 regulations
§ 55, via a special supply point with fault cur-
rent safety switch.

Install only in well aerated rooms, but not in living areas and recreation rooms!

Put the operating switch into "

I"

position (= heating operation)

The supply air fan starts.

Press down pin of thermoelectric
gas valve (safety pilot).

After approx. 2 or 3 sec. the piezo
igniter is to be actuated (possibly
several times) with the pin still
held down, until a formation of fla-
mes has occured.

After the formation of flames still hold down the pin for
approx. 10 seconds, until the thermoelectric flame-
monitoring has started.

Do not release the pin before this.

If the flame is extinguished after the pin has been re-
leased, repeat the ignition procedure after having wai-
ted for approx. 1 minute. Then keep the pin pressed
down a little longer.

Close all the cylinder valves and
stop valves of the supply line.

Important Hint!


Make sure that the supply air can be freely sucked
and the heated air can be blown off without pro-
blems.


Make sure to keep the safety distance from combu-
stible and inflammable materials and to observe the
local fire protection codes.

The setting can also be continuously changed during the
unit operation.

Setting/Regulation of Heating Capacity


Set desired heating capacity at the continuous "Power-
Regulation".

Turn to the left:

larger heating capacity

Turn to the right:

smaller heating capacity

Put the operating switch into position "

II".


In this position only the supply air fan
runs and the unit can be used for air cir-
culation.


Heating is not possible!

Ventilation

Let the flame burn out.

Put the operating switch into "0"
position (= Off) and unplug the
mains plug from mains socket.

Shut-down

This manual is related to the following products: