REMKO ETF 360 User Manual
Page 9

9
Electrical connection
■
The units operate on 230 V
AC/50Hz
■
Electrical connection
takes place using the
fi tted power cord
with safety plug.
■
Extension of the connecting
cable must only take place by
qualifi ed electricians, taking into
account the cable length, unit
installed load and local use.
s
s
s
Control panel
The control panel contains all
controls and respective indicator
lights.
“Container full” indicator
“Hot gas defrost” indicator
“Timer activated” indicator
Temperature indication and
time setting display
Relative humidity indication
and setting display
“Power ON/OFF” button
Fan speed button
“1 to 24 hour” timer button (in
1 hour steps)
Button for setting hygrostat 30
to 90% RH in 5% steps
Button for indication in °C or °F
Switching on the units
■
Connect the mains plug to a
correctly fused mains socket-
outlet.
■
Press the Power button [].
■
Select the required air volume
(min/max) by pressing the
button [].
Electrical connection must take
place to supply points using a
residual-current protective unit
according to VDE 0100, part 704.
For installation of the units in damp
areas such as utility rooms, shower
rooms or similar, the units must be
protected with a residual-current-
operated circuit-breaker complying
with the requirements.
nOTE
At room temperatures below
10 °C
and a relative humidity
below
40 %
, economical/
effi cient use of the unit is not
ensured.
nOTE
After reaching the required
humidity, the compressor
switches off and air circulation
continues..
nOTE
The units generate a short
beep on connection to the
mains supply and all indicators
fl ash once.
nOTE
Set the humidity
The dehumidifi cation capacity
depends solely on the room
conditions, room temperature,
relative humidity and observance
of the information in the chapter
“Installation”.
The higher the room temperature
and relative humidity, the greater
the dehumidifi cation capacity.
For use in living areas, a
humidity of about 45 to 60% is
recommended.
In warehouses, archives, etc., a
humidity of 40 to 45% should not
be exceeded.
■
Select the required humidity (%
RH) with the buttons [].
The set value is indicated
for about 10 seconds on the
display
[].
■
The humidity can be set in steps
of 30 - 90% RH.
■
In a normal operating mode,
the current humidity is
indicated on the display [] in
% RH.
■
The current room temperature is
indicated on the display [] in
°C or °F.
Indication selection can be made
by pressing the button [].
All cable extensions must only
be used uncoiled or unwound.
aTTEnTiOn
!
To avoid overheating, the
air outlet grille must not be
covered when the unit is in
operation.
aTTEnTiOn
!