Care and maintenance, Transporting the unit – REMKO ETF 360 User Manual
Page 12

12
REMKO ETF 360/460
For easy and convenient transport,
the units are provided with four
transport rollers and additional
recessed grips.
■
The unit must be switched off
and the plug disconnected from
the mains socket prior to each
change of location.
■
The condensation collector
must be emptied completely.
■
As long as residual moisture is
still present in the evaporator
or water is present in the
condensation collector, the
units must only be transported
upright.
■
The transport rollers are only
suitable for use on even and
level surfaces.
■
The units must be carried if
surfaces are uneven.
All moving parts are provided
with low-maintenance permanent
lubrication. The entire refrigeration
system is hermetically sealed
and must only be repaired by
authorised specialist companies.
■
Observe regular care and
maintenance intervals
■
Depending on the particular
operating conditions, the
units should be tested by an
expert for reliable operation as
necessary, but at least once a
year
■
Only clean the units dry or with
a moist cloth.
Do not use a jet of water!
■
Do not use caustic cleaning
agents or those containing
solvents
■
Only use suitable cleaning
agents to remove heavy fouling
■
Regularly check the air inlet and
outlet grilles for fouling.
Clean or replace as necessary!
Care and maintenance
Regular care and maintenance
is a basic precondition for a
long useful life and trouble-
free operation of the unit.
Cleaning the condenser and
evaporator
For cleaning the interior of the unit
and to gain access to the electrical
components, it is necessary to
open the unit housing.
■
Clean the condenser and
evaporator by either blowing
out with air, vacuuming or
using a soft brush.
Do not use a jet of water!
■
Carefully clean the internal
surfaces of the units, collection
tray with condensation pump
float, fan and fan housing.
■
Check all unit components for
possible damage and repair if
necessary.
■
Carefully refit all previously
removed components in the
reverse order.
Transporting the unit
nOTE
Only authorised specialists
may undertake repairs and
maintenance.
nOTE
Attention must be paid to
dripping condensation.
After switching off the unit,
the evaporator can continue to
defrost under the influence of
the ambient temperature.
nOTE
The fin exchanger must be
cleaned with particular care
as the delicate aluminium fins
bend easily.
nOTE
Before carrying out work on
the units, the mains plug must
be disconnected from the
mains socket.
aTTEnTiOn
!
After carrying out all work on
the units, an electrical safety
test must be carried out in
accordance with VDE 0701.
aTTEnTiOn
!
The power cord must never
be used for pulling or fixing
purposes.
aTTEnTiOn
!