Installation, Commissioning – REMKO ETF 360 User Manual
Page 8

8
REMKO ETF 360/460
installation
For optimal, economical and
reliable operation of the unit, the
following information must be
observed in any event:
■
The units must be installed
stable and horizontal to ensure
unhindered condensation
drainage.
■
The units should be placed in
the centre of the room where
possible to ensure optimal air
circulation.
■
It must be ensured that the
room air can be sucked in and
blown out freely.
■
A minimum distance of 50 cm
to walls must be maintained in
any event.
■
The units should not be installed
in the immediate vicinity of
radiators or other heat sources.
■
Optimal room air circulation
is achieved when the units
are installed about 1 m above
ground.
■
The room to be dried or
dehumidified must always
be closed from the ambient
atmosphere.
■
Open windows, doors, etc., as
well as frequently entering and
leaving the room should be
avoided as far as possible.
■
The units must not be used
in dusty, chlorine or ammonia
containing atmospheres.
■
The unit output depends
solely on the room conditions,
room temperature, relative
humidity and observance of the
installation instructions.
Min. wall di-
stance 0.5 m
Maintain distance to radiators or
other heat sources.
Keep windows and doors closed!
Diagram showing installation of the REMKO dehumidifier
Commissioning
Prior to each commissioning or
depending on the local conditions,
the air inlet and outlet grilles must
be checked for clogging.
Important information prior to
commissioning
■
Do not pull at the power cord.
■
After switching on, the units
operate fully automatically until
switched off controlled by the
hygrostat or float switch of the
full condensation collector.
■
The condensation collector
must be fitted correctly.
The unit will not function if the
condensation collector is not
fitted correctly!
■
If the units are to operate
continuously with an external
condensation connection, the
respective chapter on page 11
must be observed.
nOTE
Clogged grilles and filters must
immediately be cleaned or
replaced.
In order to prevent compressor
damage, the units are
provided with reclosing
protection, which prevents
immediate reconnection
of the compressor after
disconnection.
The compressor initially
switches on again after a delay
of about 3 minutes!
nOTE