Decommissioning – REMKO ETF 360 User Manual

Page 11

background image

11

The factory supplied hose length is
5 metres.
This can be extended on site to
max. 10 metres if required.

A height different of up 5 metres
can be bridged with the installed
condensation pump.

Press the Power button [].
-All indicators and unit functions
are now switched off-

The units must be
disconnected from
the supply if they
are not going to be
used for extended
periods of time.

The condensation collector must
be emptied completely and dried
with a clean cloth.

Pay attention to subsequently
dripping condensation!

Prior to possible storage, the units

must be cleaned thoroughly and
dried.

The internal collection tray must be
emptied of residual condensation
prior to each change of location.
To do this, open the condensation
connection with the screw cap [A]
and the sealing plug [B].
Tilt the unit back slightly and
empty the residual condensation
into a suitable container.

The condensation connection must
subsequently be carefully closed
again in reverse order.

For storage purposes, the units
should be covered with plastic
sheeting/foil or cotton cloth and
stored in an upright position in a
protected and dry location.

Continuous operation with
external condensation drain

The units have a condensation
connection at the rear.
A supplied (1m) special drain hose
can be connected at this point.

1. Unscrew the screw cap [A] (turn

counter-clockwise).

2. Pull the sealing plug [B] out of

the connection.

3. Push the smooth end of the

drain hose through the back of
the screw cap [A].

Decommissioning

It must be ensured that the
drainage hose is routed to the
drain with a gradient to ensure
that the condensate is able to
fl ow out freely!

aTTEnTiOn

!

After connecting the adapter

[SA], the pump is ready to use

and can immediately pump

water.

aTTEnTiOn

!

The units must only be
stored in upright in a suitable
location protected from dust
and direct sunlight.

nOTE

The pump will only function

when the supplied connection

adapter [SA] is correctly con-

nected.

nOTE

Continuous operation via the
internal condensation pump

For uses at locations with no drain,
the units are provided with a
condensation pump specifi cally for
this purpose.
This allows various condensation
drains to be provided to suit the
conditions locally.
The patented condensation pump
connection panel [KP] is located at
the rear of the units.
Insert the supplied connection
adapter [SA] here.

4. Screw the drain hose with

the screw cap [A] to the
connection..

A

B

The condensation should
preferably be discharged to a lower
drain in unsupervised continuous
operation.
When using an external collection
container (tray, bucket, etc.), the
unit must be raised appropriately.

KP

SA