5

Electrical connection

The units operate

on 230V
AC/50 Hz

Electrical connection takes place

using the fitted power cord
with safety plug.

Cables must only be extended

depending on the cable length,
unit rating and taking local use
into account.

Installation

For optimal and reliable unit
operation, the following
information must be observed in
any event:

The units must be installed

stable and horizontal to
ensure unhindered condensate
drainage.

The units should be placed

in the centre of the room if
possible to ensure optimal air
circulation.

It must be ensured that the

room air can be sucked in and
blown out freely.

A minimum distance of 40 cm

to walls and 60 cm above the
unit must be maintained in any
event.

The units must not be installed

in the immediate vicinity of
radiators or other heat sources.

Optimal room air circulation is

achieved when the units are
installed about 1 m above the
ground.

The room to be dried or dehu-

midified must always be closed
from the ambient atmosphere.

Open windows, doors, etc., as

well as frequently entering and
leaving the room should be
avoided as far as possible.

The units must not be used in

dusty, chlorine or ammonia-
containing atmospheres.

The unit output depends

solely on the room conditions,
room temperature, relative
humidity and observance of the
installation instructions.

ATTENTION

All extension cables must only
be used uncoiled.

wall distance

minimum 0.4 m

maintain distance to radiators or

other heat sources.

keep windows and doors closed!

Diagram showing installation of the REMKO dehumidifier

NOTE

For installation of the units
in damp areas such as utility
rooms, shower rooms or
similar, the units must be
protected with a residual-
current-operated circuit-
breaker complying with the
requirements.

ATTENTION

The unit must not be discon-
nected from the supply before
the after-running time of 2
minutes has elapsed.