Installation – REMKO ASF 100 User Manual
Page 5
5
Electrical connection
■
The units operate
on 230V
AC/50 Hz
■
Electrical connection takes place
using the fitted power cord
with safety plug.
■
Cables must only be extended
depending on the cable length,
unit rating and taking local use
into account.
Installation
For optimal and reliable unit
operation, the following
information must be observed in
any event:
■
The units must be installed
stable and horizontal to
ensure unhindered condensate
drainage.
■
The units should be placed
in the centre of the room if
possible to ensure optimal air
circulation.
■
It must be ensured that the
room air can be sucked in and
blown out freely.
■
A minimum distance of 40 cm
to walls and 60 cm above the
unit must be maintained in any
event.
■
The units must not be installed
in the immediate vicinity of
radiators or other heat sources.
■
Optimal room air circulation is
achieved when the units are
installed about 1 m above the
ground.
■
The room to be dried or dehu-
midified must always be closed
from the ambient atmosphere.
■
Open windows, doors, etc., as
well as frequently entering and
leaving the room should be
avoided as far as possible.
■
The units must not be used in
dusty, chlorine or ammonia-
containing atmospheres.
■
The unit output depends
solely on the room conditions,
room temperature, relative
humidity and observance of the
installation instructions.
ATTENTION
All extension cables must only
be used uncoiled.
wall distance
minimum 0.4 m
maintain distance to radiators or
other heat sources.
keep windows and doors closed!
Diagram showing installation of the REMKO dehumidifier
NOTE
For installation of the units
in damp areas such as utility
rooms, shower rooms or
similar, the units must be
protected with a residual-
current-operated circuit-
breaker complying with the
requirements.
ATTENTION
The unit must not be discon-
nected from the supply before
the after-running time of 2
minutes has elapsed.