beautypg.com

REMKO SLV11-88-2 User Manual

Page 8

background image

8

Adjusting the Air Flap (SL 55/2 and SL 66/2)

Setting the Conectron LKS 130-2 adjustment motor
The adjustment motor has the activation function “Air
quantity level 1” and an activation contact for the
“Magnetic valve level 2”.
The adjustment motor remains in this position when the
control is switched off in the “Air quantity level 2” posi-
tion and, when restarted, returns to the “Air quantity
level 1” position.

Setting “Air quantity level 1”
Adjustment lever blue

1.

Unplug the 4-pin multi-purpose connection.

Thermostat level 2.
2. Turn the orange adjustment lever “Air quantity Level

2” and the black adjustment lever “Magnetic valve 2”
clockwise until both

activation cams

are inititally not

pressed down so that the setting the activation cam
for the “Air quantity 1” is not blocked.

Less air Level 1:
Set the blue adjustment lever counter-clockwise to
the smaller opening angle. When the burner is run-
ning, the adjustment motor automatically adjusts.
More air Level 1:
Set the blue adjustment lever clockwise to the larger
opening angle. When the burner is running, the ad-
justment motor automatically adjusts.

Activation point “Magnetic valve 2”
Adjustment lever black

The adjustment lever for “Magnetic valve 2” is now ro-
tated back counter-clockwise and the activation point
“Air quantity 2” is placed briefly behind the “Air quantity
1” activation point. This activation point works between
the positions “Air quantity Level 1” and “Air quantity
Level 2”.

Important information

Please make sure that the activation cam from
“Magnetic valve 2” is not pressed before activation cam
“Air quantity level 1” because otherwise the “Magnetic
valve 2” in the “Air quantity 1” area opens and the
burner would run with an insufficient quantity of air.

Adjustment lever “blue” Level 1

Adjustment lever “orange” Level 2

Adjustment lever “black” magnetic valve Level 2

Opening scale

Opening indicator

When assembling the burner, the opening scale was
fixed in such a way that the position 0° corresponds to a
closed air flap. When the burner is shipped, an opening
angle of 30° “Air quantity level 1” is preset for the air
flap.
The preset opening angle for the “Air quantity level 2” is
50°.

Setting “Air quantity level 2”
Adjustment lever orange

1. Turn back the adjustment lever for the “Air quantity

level 2” counter-clockwise.

2. Determine the activation point for the “Air quantity

level 2” based on the burner capacity behind the acti-
vation point “Magnetic valve 2”.

3. Plug in the 4-pin multi-purpose connection of Ther-

mostat level 2 again.

The adjustment motor runs via “Magnetic valve 2” to
the position “Air quantity level 2”.

Less air Level 2:

Set the orange adjustment lever counter-clockwise
to the smaller opening angle. Switch to the burner
briefly back to Level 1. After the unit is switched back
to Level 2, the adjustment motor’s speed adjusts to
the changed quantity of air.
More air Level 2:
Set the orange adjustment lever clockwise to the
larger opening angle. When operating at Level 2, the
speed of the adjustment motor adjusts automatically.

G

Make sure that there are no mechanical defects on
the adjustment motor or the air flap otherwise the
adjustment motor will be damaged.