Terminal strip tmo 720-4, Terminal strip conectron lks 160 adjustment motor – REMKO SLV11-88-2 User Manual
Page 11

11
C1 = Reset condenser
FT = Release thermostat
Nozzle connection rod preheater
FW = Photo resistance
M = Burner motor
MV1 = Magnetic valve 1st level
MV2 = Magnetic valve 2nd level
ÖV = Nozzle connection rod preheater
SA = External malfunction display
WS = 7-pin plug to warm air generator
Z = Ignition transformer
Control relay TMO 720–4 only model size SL 88/2
12 13
6
A
8
1
2
3
8 5 7 9
8
20
8
14 15 16
4
Burner motor
7-pin connector
in accordance
with DIN 4791
Caution!
4-pin plug is only used
internally and has to be
plugged in during
operation
MV2
400 V / 3~
L1
N
T1
T2
S3
B4
L1
N
T1
T2
S3
B4
MV1
ZT
FW
B5
T6
T7
T8
B5
T6
T7
T8
Terminal strip TMO 720-4
3
10 11 N
2
8
14 5 4
Terminal strip Conectron LKS 160 adjustment motor
Control line to
warm air generator
L1
L2
N
L3
L1
L2
N
L3
Connection line to
warm air generator
Wiring diagram key
All REMKO standard heaters must always be operated
with nominal load.
All two-level burner models may only be operated in the
second burner level.
The first burner level may only be used as start-up re-
lief!
Important information.
We reserve the right to make changes to dimensions and design in the interest of technical progress.
5-pin connector
in accordance
with DIN 4791