beautypg.com

Terminal strip tmo 720-4, Terminal strip conectron lks 160 adjustment motor – REMKO SLV11-88-2 User Manual

Page 11

background image

11

C1 = Reset condenser
FT = Release thermostat
Nozzle connection rod preheater
FW = Photo resistance
M = Burner motor
MV1 = Magnetic valve 1st level
MV2 = Magnetic valve 2nd level
ÖV = Nozzle connection rod preheater
SA = External malfunction display
WS = 7-pin plug to warm air generator
Z = Ignition transformer

Control relay TMO 720–4 only model size SL 88/2

12 13

6

A

8

1

2

3

8 5 7 9

8

20

8

14 15 16

4

Burner motor

7-pin connector

in accordance
with DIN 4791

Caution!

4-pin plug is only used

internally and has to be

plugged in during

operation

MV2

400 V / 3~

L1

N

T1

T2

S3

B4

L1

N

T1

T2

S3

B4

MV1

ZT

FW

B5

T6

T7

T8

B5

T6

T7

T8

Terminal strip TMO 720-4

3

10 11 N

2

8

14 5 4

Terminal strip Conectron LKS 160 adjustment motor

Control line to

warm air generator

L1

L2

N

L3

L1

L2

N

L3

Connection line to

warm air generator

Wiring diagram key

All REMKO standard heaters must always be operated
with nominal load.
All two-level burner models may only be operated in the
second burner level.
The first burner level may only be used as start-up re-
lief!

Important information.

We reserve the right to make changes to dimensions and design in the interest of technical progress.

5-pin connector

in accordance
with DIN 4791