beautypg.com

Shutting down the unit – REMKO HTL 400 User Manual

Page 11

background image

11

4

NOTE

After all adjustment tasks the
doors must be closed.
In order to prevent
unauthorized operation, the
doors should also be locked.

The inlet fan continues to run
to cool the combustion
chamber and the heat ex-
changer and does not switch
off until later. The fan may re-
start several times until finally
switching off.
Never interrupt the mains
connection before the entire
cool-down phase comes to an
end (except in emergency
situations).
Damage caused to the device
by overheating renders the
guarantee null and void.

NOTE

4. In the case of longer down
times, lock the closing lid of
the exhaust connection.

3

1

Shutting Down the Unit

Heating with a room
thermostat (accessories)

The devices operate fully auto-
matically depending on the room
temperature.

1. Remove jumper plug 2.

2. Connect plug 3 of the room
thermostat 4 to the thermostat
socket 1 at the switch cabinet.

3. Place the room thermostat 4 at
a suitable location in the room.
The thermostat sensor must not
be within the hot air stream
and should also not be placed
on a cold floor.

4. Set the required temperature on
the room thermostat 4.








5.

Turn the operating switch to the

required operation position
“1” (low heating stage) or
“2” (high heating stage).

If heat is required and after a brief
initial ventilation of the burner the
device switches on and continues
to run completely automatically.

1. Turn the operating switch to
the „0“ position (off).

2. Close off the
fuel supply at
the device and
oil tank.

3. In case of longer downtimes,
disconnect the device from the
power supply.