7

Starting


Only individuals who have been sufficiently trained in
the respective area may operate the units and monitor
the containers and storage of the cylinders.

Please also observe the following.
Make sure that the operator is aware of potential

dangers when handling liquid gas.

The unit may only be installed in well-ventilated

rooms; it may not be installed in residential rooms or
similar spaces!

For optimum unit operation, the device should not be

operated at an ambient temperature above 25 °C.

Make sure to maintain a safe distance to combusti-

ble and flammable materials and comply with local
fire codes.

1. Set the operating switch to "I".

Heating mode.
The air supply fan starts.

2. Press and hold the pressure pin 2

of the thermoelectric gas valve.
Safety pilot.

3. Hold the pressure pin down for

approx. 2 or 3 sec. and then press
the piezo electric igniter until a
flame appears.

1. Set the operating switch to "0".

Off.

2. Plug the unit in to a power socket

with the right connection.

230V/1~ 50Hz.

4. After a flame has appeared, continue holding down

the pressure pin for approx. 10 - 15 seconds until the
thermoelectric flame monitoring function has started.

5. Do not release the pressure pin before this.
6. If the flame goes out once you release the pressure

pin, repeat the ignition process after waiting approx.
1 minute.

7. Keep the pressure pin pressed down a little longer.

The unit must be connected to the power supply
via a special supply point with fault current safety
switch.

*

Connecting the unit to the power supply

Heating

Setting and regulating the heat output

1. Set the heat output gradually using the adjustable

“power regulation”.

2. Please note: this setting can also be gradually

changed while the unit is in operation.

Turn to the left:
Increases heat output


Turn to the right:
Lowers heat output

Ventilation

In ventilation mode, only the air supply fan runs and the
unit can be used for air circulation.

Safety Mechanism


Should overheating occur, the safety temperature lim-
iter (STB) interrupts the gas supply and locks the unit’s
electrical system. All unit functions are switched off.

1. Remove the protective cap 1

2. Press the reset button 2.

3. Replace the protective cap.

1

2

1. Set operating switch to "II".
2. Please note: it is not possible to

heat!

Important Information

Make sure that the air supply can be freely suctioned in
and the heated air blown out.

The unit’s air intakes and outlets may not be constricted
or equipped with hoses or pipes.

Before resetting the unit, check the operating con-
ditions to ensure that the STB temperature is not
exceeded again.

*

“RESETTING” is not possible before the sensor has
cooled down to below approx. 90 °C.
The unit is released once the protective cap has been
unscrewed by pressing the “STB-RESET“ button.

You will find a detailed table for fixing problems under
“Troubleshooting”.