beautypg.com

Shutdown – REMKO DZH 20-2 User Manual

Page 7

background image

7

1. Switch the operating

switch to the „0“
position (off).

2. In case of longer

downtimes,
disconnect the
unit from the
power mains.

Heating with room thermos-
tat (accessory)

The appliances operate fully auto-
matically depending on the room
temperature.

1. Disconnect the

jumper plug 2.

2. Connect the plug 3

of the room thermostat 4 toge-
ther with the thermostat socket
1 of the device.

3. Place the room thermostat (4)

at a suitable position in the
room.

The thermostat sensor may not
be in the path of direct hot air
flow and should not be placed
directly on a cold foundation.

4. Adjust the desired temperature

on the room thermostat.

5. Switch the

operating switch to the
„I“ position (on).



In case heating is needed, the unit
now switches on automatically and
then off when the desired room
temperature is reached.

Shutdown

CAUTION

Never interrupt the mains
connection before the entire
cool-down phase comes to
an end.
No warranty claims exist for
damage to the unit due to
overheating!

1

3

Notices regarding the safety
cut-off of the unit

The unit fuel supply takes place in
a single line system.
In this regard, the fuel supply to
the nozzle can be interrupted by
blowing air during the initial start-
up or after the fuel tank has been
completely emptied.

The automatic burner relay of the
appliances shut down due to mal-
function in this case.
This shutdown due to malfunction
is indicated by the red pilot lamp
on the control panel.

Reset the automatic burner relay
by pushing this red pilot lamp.

If the appliance does not start after
several start attempts,
read the „Trouble Shooting“
section

Refill fuel if necessary

Never (except in emergency
situations) interrupt the mains
connection before the entire
cool-down phase comes to
an end.

4

The automatic burner relay can
get unlocked after a waiting
periode of 60 sec., only.

NOTE

In case of longer downtimes or
storage of the unit, always fill
the fuel tank with heating oil
or diesel fuel.

NOTE

NOTE

The supply air fan runs to cool
off the combustion chamber
further and switches off later
on its own. The fan may run
several times until it switches
off permanently!

NOTE

This manual is related to the following products: