beautypg.com

Remko dzh, Safety notices device description – REMKO DZH 20-2 User Manual

Page 4

background image

4

REMKO DZH

Safety Notices

Device Description

When using the appliance, always observe the respective local construc-
tion and fire protection ordinances as well as the regulations of the
employers‘ liability insurance associations.

The appliances were subjected to
extensive material, functional, and
quality tests before delivery. Never-
theless, the equipment may present
a danger if it is used by untrained
personnel, improperly, or not accor-
ding to regulation!
Please observe the following
notices:

Before maintenance or servicing

work, the mains plug must be
removed from the socket

The unit may be operated only

by personnel who have been
trained in its operation

The unit must be set up and

operated in such a way that
people are not endangered by
exhaust fumes and radiated
heat and no fires can break out

The unit may be set up and

operated in rooms only if there
is a sufficient amount of air for
the combustion

The unit may be operated

without an exhaust duct only in
well-ventilated rooms. People
may not constantly be in the
mounting room
Corresponding prohibition
signs must be posted at the
entryways!

The unit may not be operated

without supervision

Mount the unit only on a
level, non-flammable base

The unit may be set up and

operated only in an environ-
ment not at risk of fire or explo-
sion

The unit may not be set up in
atmospheres containing oil,
sulphur, or salt

A safety zone of 3 m around
the exhaust and 1 m around
the unit and non-flammable
objects must be
observed

The protective air suction grille
must always be free of dirt and
loose objects

Never insert foreign matters
into the unit

The unit may not be exposed to

direct water jets, such as high-
pressure cleaning unit, and so
on

All electrical cables of the unit

must be protected from dama-
ge (e.g. due to animals)

Safety equipment may neither

be bridged nor blocked!

Due to the design, a perma-

nent, fixed-location installation
is not intended for this type of
unit

The unit is a mobile heater and is
directly fueled with EL heating oil
or diesel fuel.
The unit works without an exhaust
connection and is solely designed
for commercial use.

The unit is equipped with a fuel
container underneath, fuel fil-
ters, maintenance-free axial fans,
high-pressure spraying furnace
with optical flame monitor, room
thermostat socket, and mains cable
with an earthing contact plug.

The unit complies with the basic
safety and health requirements of
the relevant EU stipulations and is
easy to operate.

Among other things, the devices
have the following uses:

Spot heating of

outdoor workplaces

Spot heating of

workplaces in open, non fire-
hazard production rooms and
halls

Temporary heating of rooms

with a sufficient fresh-air supply

De-icing of machines, vehicles,

and non-flammable warehouse
goods

Temperature control of parts at

risk of frost

The units may be set up only
in well-aerated rooms and not
in living areas or lounges.

CAUTION

!!