Remko dzh, Commissioning – REMKO DZH 20-2 User Manual

Page 6

background image

6

REMKO DZH

Heating without room ther-
mostat

The unit works in continuous
operation.

1. Connect the jumper plug 2 in-

cluded in deliver with the ther-
mostat socket 1 on the device.

2. Switch the

operating switch to the
„I“ position (on).

Safety distances

To guarantee a safe unit

operation, a safety distance of
1 metre around the device must
be observed

To blow out the unit, a distance

of at least 3 metres must be
observed

The floor and ceiling must be

fire-resistant

The intake and exhaust cross-

sections may not be pinched or
blocked by foreign objects

Commissioning

2

1

NOTE

The electrical connection of
the unit must be performed at
a certain supply point with an
earth-leakage circuit breaker
according to VDE 0100 § 55.

Before commissioning, the unit
should be checked for noticeable
defects of the operating and safety
appliances, as well as for proper
mounting and correct electrical
connection.
Someone who has been
sufficiently trained in the corres-
ponding handling of the unit must
be assigned with its operation and
monitoring.

Connecting the devices to the
power supply

1. Switch the operating

switch to the „0“
position (off).

2. Connect the

mains plug of the
device to a
properly installed

and secured
mains socket. 230 V/50 Hz

CAUTION

In case of defects that endan-

ger the operating safety of the

unit, the operation of the unit

must be shut down immedi-

ately and the supervisor must

be informed!

CAUTION

All cable extensions may be
used only when unrolled.

Paraffin formation at low out-
door temperatures

Even in case of low temperatures,
free-flowing heating oil must be
available in sufficient quantities.

An optional tank heater is
available as a REMKO accessory.

Fill the fuel container with clean

heating oil or diesel fuel

Do not use biodiesel

Use only clean, suitable contai-
ners for the filling procedure

Before the start-up of every appli-
ance and every filling of the tank,
the fuel filter must be checked for
soiling or paraffin formation.

The filter is located directly next to
the tank filler neck. The fuel tank
may be filled only when the tank
filter has been inserted into the
filler neck.

NOTE

Paraffin formation can
already take place at tempera-
tures below 5°C.
Corresponding measures and
precautions must be taken to
prevent it.

The appliances may not be
placed and runed in fire and
explasition danger vicinities.

CAUTION

!

NOTE

In case of overheating of the
devices is a safety shutdown of
the burner relay.

NOTE

Only clean fuel through a fun-
nel with a fine filter fill.