The equipment is shipped in sturdy

transport packaging. Immediately

check the equipment on delivery

and make a note of any damage

or missing parts on the delivery

note. Inform the forwarding agent

and contractual partner. Warranty

claims at a later date will not be

accepted.

The MD 261-351 room air

conditioning units have a REMKO

MD...AT outdoor component as

well as an indoor unit MD...IT.
The outdoor component serves

to output the heat extracted by

the indoor unit from the room

being cooled. In heater operation,

the heat taken up by the outdoor

component can be discharged

by the indoor unit into the room

to be heated. In both operating

modes, the performance of the

compressor is adjusted precisely

to the requirement which thereby

regulates the set temperature with

minimal temperature variation.

This "inverter-technology" enables

power saving over a conventional

split-system and also reduces noise

emissions to a particularly low

level.

The outdoor component can be

installed outside or in indoor areas,

if certain requirements are met.

The indoor unit is designed for the

upper wall area in the interior. It

is operated via an infrared remote

control.
The outdoor component consists

of a refrigerant circuit with

compressor, fin liquefier, liquefier

fan, reverse flow valve and flow

regulator. The outdoor component

is controlled via the regulation of

the indoor unit.
The indoor unit consists of

a fin evaporator, evaporator

fan, regulation system and

condensation pan.
Floor consoles, wall consoles,

refrigerant pipes and condensation

pumps are available as accessories.

Unit description

Transport and
packaging

The connection between the indoor unit and the outdoor component
made with refrigerant pipes.

Schematic of refrigerant circuit in indoor unit - cooling

Vaporiser fan

Connection to suction pipe

Connection to injection pipe

Vaporiser

Schematic of exterior refrigerant circuit

M

M

Liquefier fan

Reverse flow valve

Liquefier

Filter dryer

Capillary tube flow regulator

Connection

valve

Injection pipe

Connection

valve

Suction pipe

Compressor

Connection

Manometer

Outdoor

component

System layout

Stop valve

Indoor unit

Liquefier fan

Outdoor area

Injection pipe

Suction pipe

Control cable

Mains cable

Condensation pipe

Indoor area

Condensation pipe

5