beautypg.com

Installation instructions – REMKO RKL 490 DC User Manual

Page 7

background image

Installation instructions


The device is supplied in a fully op-
erational condition and is equipped
as standard with a connection pipe
linking the indoor and outdoor de-
vices, meaning that it is ready for
use. The scope of delivery includes
various accessories for mounting
the outdoor unit.

The indoor unit

The indoor unit is positioned at the
desired location with the air dis-
charge side pointing into the room.
When positioning, ensure there is
a minimum gap of 20 cm around
the device.


Connector pipes

The connector pipes can be
laid through a tilted window
or through a gap in the door.
The connector pipe can be sepa-

rated from the indoor unit, mean-
ing that there is the additional
option of fitting it to a wall open-
ing (Ø min. 60 mm).

Please note the following information
when laying the connector pipes:

The connector pipes may not
be jammed in or kinked.

There may not be any ten-
sion of other mechanical stress
exerted on the connector pipes.

The pipe insulation and the
protective jacket may not be
damaged.

Outdoor component

The outdoor unit expels the heat
from the room into the outside air.
In order to do so, the outdoor unit
can be positioned on the ground
or mounted on an external wall.

Installation on the ground

It is not necessary to use any
mounting accessories when install-
ing the outdoor unit on a patio or
balcony.

The outdoor unit should be po-
sitioned vertically and protected
from direct sunlight. A minimum
gap of 20 cm should be main-
tained from the air discharge side
to the wall.

It must be ensured that the air can
be discharged freely (min. 50 cm
gap to any obstacles).
The connecting pipe is fed through
a gap in the window or door
(Fig. 2 and 3)

.

20 cm

20 cm

3 Example assembly outdoor unit

2a Absence of minimum gap

2 Minimum clearance to wall

4. Take the condensate drain hose

on the back of the indoor unit
out of its bracket and remove
the plug.

5. Allow the condensate to drain

downwards into a drain or con-
tainer.

Ensure that the external
container does not overflow.
This could result in water
damage.

!

CAUTION

6. Switch the unit on by means of

the "I / 0" button.

7. Set the temperature selection

switch to the lowest nominal
temperature.

8. Set the "MODE" button to the

lowest fan speed "LO".

7