The system can be operated by means of the control panel on the device or via the standard infrared remote
control unit. The functional operation of the buttons among themselves is identical, however, the designation
can vary. The batteries must be correctly inserted before the infrared remote control is used.

Operation

Legend

"ON / OFF" button

"MODE" button

(Fan speed – mode)

The fan speed is indicated by

means of LEDs in the selected

modes AUTOžHIžMEDžLO or

circulated air modežFAN.

LED "COMP. ON"

(Compressor operation)

The controller controls the cool-

ing output by means of switch-

ing the compressor on or off.

Compressor operation is indicat-

ed by means of the LED. If the

LED flashes, the compressor will

be activated in max. 3 mins.

Button "

▼ ▲"

Temperature setting

The desired nominal temperature

can be set with the

▼▲ buttons

in steps of 1°C between 16 and

30°C.

On and off timer

The timer function can be used

to switch the device on or off

automatically in hourly intervals

("

▼▲" buttons) by means of

pressing the "SET" button. The

function can be used to program

the switch-on timer when the

device is off and the switch-off

timer when the device is on, for

up to 24 hours. Both timers can

be deleted by means of pressing

the "RESET" button.

AUTO SWING button

The direction of the discharged

air via the oscillating fins can be

adjusted to fixed or oscillating

by pressing the "AUTO SWING"

button.

LED "DRAIN WATER"

If the pump is unable to trans-

port the collected condensate

then this is signalised via an

acoustic alarm in combina-

tion with the flashing "DRAIN

WATER" LED. The device will

be operational again after the

container is emptied by means

of the condensate drain.

Display

The display shows the set nomi-

nal temperature or the residual

time of a programmed timer.

Infrared receiver

The device receives the signals

from the infrared remote con-

trol via the sensor.

FAN button

The ventilator speed can be

adjusted by means of pressing

the "FAN" button.

Cooling mode
1. Switch the unit on by means of

the "I / 0" button.

2. Set the temperature selection

switch to the desired nominal
temperature.

3. Select the desired fan mode

to AUTO, HI, MED or LO by
means of the "MODE" button.

Circulated air
1. Switch the unit on by means of

the "I / 0" button.

2. Select FAN mode by means of

the "MODE" button.

The outdoor unit can remain in the
room in circulated air mode.
However, do not hang the outdoor
unit onto the indoor unit.

Dehumidifying mode
Position the indoor unit and the
outdoor unit in the room that is to
be dehumidified.
1. Ensure that the indoor unit can-

not extract warm air from the
outdoor unit.

2. Do not hang the outdoor unit

onto the indoor unit.

3. Please observe: The condensate

formed during dehumidifica-
tion may not be pumped to the
outdoor unit as otherwise it will
be dissipated back into the air
in the room or may run out of
the outdoor unit.

 

Control panel

FAN

TEMP.

ON/OFF

FUZZY

C

TIMER

MODE

infrared remote control

Infrared transmitter

REMKO RKL

6