Shut-down, Troubleshooting and customer service – REMKO RKL 490 DC User Manual
Page 11
Shut-down
Temporary shut-down
If it is planned to shut down the
equipment for longer periods e.g.
during the winter, proceed as fol-
lows:
1. Allow the equipment run for
2-3 hours in circulation mode.
This extracts any residual hu-
midity from the unit.
2. Shut down the equipment by
pressing the "I / 0" button on
the operating panel. Only then
The unit has been manufactured using state-of-the-art production methods and tested several times to ensure
its correct function. If malfunctions should occur, please check the unit as detailed in the list below. If all func-
tional checks have been carried out and the device still fails to operate properly, then please notify your nearest
specialist dealer.
Troubleshooting and customer service
Fault
Possible cause
Remedial measures
The unit does not start
Mains failure
Check voltage and if necessary wait until
power is back on
Mains fuse or controller fuse faulty
Arrange to have exchanged
Mains plug not inserted in socket
Insert mains plug
Condensate container full, display "DRAIN
WATER" flashes
Empty container via condensate drain hose
Timer mode active
Wait for timer period to expire or
press "I / 0" button again
The unit is running with
Reduced ventilation output
Used air or outlet openings soiled or blocked
by foreign bodies
Clean the openings
Remove foreign bodies
Filter soiled
Clean the filter in accordance with the instructions
Outdoor unit soiled
Clean the fins on the inside of the outdoor
unit
Cooling load of the room excessive
Reduce the thermal load
Condensate leaks out of
the unit
Device standing at an angle
Position vertically, ensure stable positioning
Plugs missing from condensate
drain hose
Seal the hose so that it is watertight again
should you pull out the mains
plug and wind up the cable.
3. Empty the internal condensate
container via the condensate
drain hose on the rear side of
the indoor unit.
4. Make sure that there is no
condensate in the outdoor unit
before storing the indoor and
outdoor unit indoors. To drain
the condensate, remove the
plug from the outdoor unit.
5. Clean the filter and the plastic
surfaces.
6. Hang the outdoor unit onto the
indoor unit.
7. Cover the equipment with
a synthetic tarpaulin to protect
it against dust.
8. Store the equipment in a cool
and dry location away from
direct sunlight.
Permanent shut-down
The entire system should only be
dismantled by a specialist firm
familiar with all environmental
aspects involved.
REMKO GmbH & Co. KG or your
sales partner will be be pleased to
provide details of refrigerant spe-
cialists in your area.
Never switch off the equip-
ment by pulling out the mains
plug.
NOTE
11