Remko mkt – REMKO MKT 250 User Manual
Page 8
REMKO MKT
9
CAUTION
■
The function of the device was precisely
checked several times at the factory. If
malfunctions that are not described in
the “Trouble Shooting“ chapter (s. p.
7) still appear, contact your dealer or
contractual partner.
■
In order for REMKO to assume the
warranty, the “Warranty Certificate“
included in delivery must be completely
filled out and sent to REMKO GmbH &
CO KG immediately after purchasing or
commissioning.
Warranty
Electrical wiring diagram
The manufacturer is not li-
able for damage that occurs
due to nonobservance of
manufacturer instructions or
the legal requirements or due
to unauthorised changes to
the device.
Fig. 18 Electrical wiring diagram
Technical dimensions and design sub-
ject to alteration
Control panel
Evaporator fan
Condenser
Red
Orange
Yellow
White
Red
Red
Red
Blue
Blue
Blue
Blue
Condenser
Condenser
Compressor
Evaporator fan
Reservoir motor
Mains plug
White
Blue
White
Blue
Microswitch
Temperature
sensor
J003
J002
J001
Hi Med Lo
RL101
L
N
E
J01
Brown
L
COMP
To take the device out of service,
deactivate it first by pressing the “Power“
button. Then pull the mains plug.
If the device must be shut down for a
longer period of time, for example, for
storage during the winter, observe the
following:
1.
Let the machine run for about two
hours in the “Fan“ mode to dry the sur-
face of the evaporator plate fins. In this
way, the residual moisture is removed
from the device and you can prevent
unpleasant smells during recommission-
ing.
2.
Switch off the device, pull the mains
plug, and roll up the mains supply line.
3.
Drain the condensate (s. p. 6).
Taking out of service
L