Troubleshooting

Regarding the indicator lamps (continued)

• When the interior portion has become overheated, for safety

purposes, the projector is automatically shut down, and the indicator lamps

may also be turned off. In such a case, disconnect the power cord, and wait at

least 45 minutes. After the projector has sufficiently cooled down, please make

confirmation of the attachment state of the lamp and lamp cover, and then turn

the power on again.

If the projector is used at an altitude of about 1600 m (5250 feet)

or higher, set ALTITUDE of the SERVICE item in the OPTION menu to HIGH (57).

Otherwise, set it to NORMAL.

NOTE

POWER

indicator

LAMP

indicator

TEMP

indicator

Description

Blinking

In

Red

or

Lighting

In

Red

Turned

off

Lighting

In

Red

There is a possibility that the interior portion

has become heated.

Please turn the power off, and allow the projector to

cool down at least 20 minutes. After the projector has

sufficiently cooled down, please make confirmation of

the following items, and then turn the power on again.

• Is there blockage of the air passage aperture?

• Is the air filter dirty?

• Does the peripheral temperature exceed 35°C?

• If the projector is used at an altitude of about 1600 m

(5250 feet) or higher, set ALTITUDE of the SERVICE

item in the OPTION menu to HIGH (57). If the

projector is used with a wrong setting, it may cause

damage to the projector itself or the parts inside.

Lighting

In

Green

Simultaneous

blinking in

Red

It is time to clean the air filter.

Please immediately turn the power off, and clean or

change the air filter referring to the section

Cleaning

and replacing the air filter. After cleaning or changing

the air filter, please be sure to reset the filter timer.

After the remedy, reset the power to ON.

Lighting

In

Green

Alternative

blinking in

Red

There is a possibility that the interior portion

has become overcooled.

Please use the unit within the usage temperature

parameters (5°C to 35°C).

After the treatment, reset the power to ON.

Blinking In

Green

for

approx. 3

seconds.

Turned

off

Turned

off

At least 1 Power ON schedule is saved to the

projector.

Please refer to

3.1.7 Schedule Settings in the

Network Guide.