beautypg.com

Directed Electronics K10 User Manual

Page 6

background image

7

H1/11 RED (+)12V constant power input

Before connecting this wire, remove the supplied fuse. Connect to the positive battery terminal or the
constant 12V supply to the ignition switch.

N

NO

OTTEE:: Always use a fuse within 12 inches of the point you obtain (+)12V. Do not use the fuse in the har-

ness for this purpose. This fuse protects the module itself.

H1/12 RED/WHITE channel 2, 200mA (-) output

When the system receives the transmitter code controlling Channel 2 for longer than 1.5 seconds, the
red/white wire will supply an output as long as the transmission continues. This is often used to oper-
ate a trunk/hatch release or other relay-driven functions.

IIM

MPPO

ORRTTA

AN

NTT!! Never use this wire to drive anything but a relay or a low-current input! The

transistorized output can only supply 200 mA of current. Connecting directly to a solenoid,
motor, or other high-current device will cause it to fail.