SPECIFICATIONS

GENERAL SPECIFICATIONS

OUTPUT SPECIFICATIONS

Input voltage

2

36~75V

Voltage accuracy

Typical ±1.0%

Frequency

Line regulation

Typical 350KHz

Typical ±0.01%

Isolation Capacitance

Load regulation

In/Out 2250V

Typical ±0.05%

MTBF

Ripple & noise

Bellcore TBD

Typical 150

mV

Typical

OTP

Current limits

Typical 115°C

130%

Typical

Size

Voltage Trim

(2.40”Ч2.28”Ч0.50”) 61.0 x 57.9 x 12.7mm

+10%, -40%

PART NUMBERING SYSTEM

H 48 S N 280

12

N R

F

A

Form

Factor

Input

Voltage

Number of

Outputs

Product

Series

Output

Voltage

Output

Current

ON/OFF

Pin

Length

Option

Code

Logic

H- Half

Brick

48V

S- Single

N- 350W

series

280- 28V

12- 12.5A

N- Negative

R- 0.170”

A - Standard
Functions

F- RoHS 6/6

P- Positive

N- 0.145”

(Lead Free)

K- 0.110”

B= no thread
heatsink mounting
hole

Space - RoHS
5/6

MODEL LIST

MODEL NAME

INPUT

OUTPUT

EFF @ 100% LOAD

91%

H48SN28012NRFA 36V~75V 12.5A 28V 12.5A

MECHANICAL DRAWING


CONTACT

:

www.delta.com.tw/dcdc

Asia & the rest of world:

USA:

Europe:

Telephone: +886 3 4526107 ext 6220

Telephone:

Phone: +41 31 998 53 11

Fax: +886 3 4513485

East Coast: (888) 335 8201

Fax: +41 31 998 53 53

West Coast: (888) 335 8208
Fax: (978) 656 3964
Email:

[email protected]

Email:

[email protected]

Email:

[email protected]

WARRANTY

Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon request from
Delta.
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor
for any infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or
otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without
notice.

2