Vi. command emulation – Posiflex PD-2300 User Manual
Page 17

6 - 1
VI. COMMAND EMULATION
This VFD customer display provides several
software programming emulation modes for display
control. The emulation mode is defined by adjusting
the DIP SW on the back as in the following table.
Switching these DIP switches may require some
proper tool or special effort. The switch positions must be changed only when
power turned off. The relationship is tabulated below.
Emulation Mode
UTC (/Futaba) Noritake Aedex (/ADM)
Epson
SW 1
on
off
on
off
SW 2
on
on
off
off
The parenthesized Futaba and ADM modes can be accessible when the
internal jumper JP3 is opened. The followings are some brief introduction of the
emulation modes as they are compared to each other for selection guide:
Mode
Futaba Noritake Aedex ADM Epson
UTC
Cursor
Blinking
Block
Blinking
Block
N.A.
N.A. Invisible
Blinking
Block
(DP)
Default mode
V. scroll
up
Ovr
N.A.
N.A.
Ovr
PT
User defined font
N.A.
2 chars
N.A.
N.A.
2 chars
2 chars
(PT)
Brightness control
YES
YES
NO
NO
YES
YES (DP)
Pass through function
YES
YES
YES
NO
YES
YES (PT)
Leading code change
YES
YES
YES
NO
NO
YES (PT)
Code page select
YES
YES
NO
NO
YES
YES
Auto scroll message
YES
YES
NO
NO
NO
YES (PT)
Timer clock
NO
NO
NO
NO
YES
YES (PT)
To display the Euro-dollar sign on the Euro code page supported models,
please select code page 13(Hex) and display code D5(Hex). Please visit our web
site http://www.posiflex.com.tw for details on software commands if required.
Push up to
switch on
SW1
SW2