beautypg.com

Dimplex DS7420 User Manual

Page 12

background image

12

www.dimplex.com

PROBLEM

CAUSE

SOLUTION

Heater Continued
Heater is not turning on

Improper operation

Refer to Operation Section

Defective heater assembly

Replace heater assembly

Defective heater on/off switch

Replace heater on/off switch

Heater is turning off after a

couple of minutes of operation

Build up of dirt/dust in heater assembly

Clean out heater assembly

Defective Motor

Replace Motor

Heater emits an odor

Normal Operation

Normal operation is when the heater emits an odor

for a brief period after the heater is initially turned on.

The heater is burning off any dust accumulated during

manufacturing or operation.

Defective heater assembly

Replace heater assembly

Heater fan turns on but heater

lacks heat

Improper operation

Refer to Operation Section

Defective thermostat

Replace thermostat

Loose wiring

Trace wiring in unit

Defective heater assembly

Replace heater assembly

Heating element is glowing red

Normal Operation

Small glowing sections of the element are considered

normal.

Defective heater assembly

If larger glowing sections are causing the heater to trip

the thermal cutout, unplug unit, discontinue use and

replace heater assembly.

Heater fan runs continuously

Loose wiring

Trace wiring in unit

Defective heater on/off switch

Replace heater on/off switch

Defective heater assembly

Replace heater assembly

Defective thermostat

Replace thermostat

Noise
Excessive noise with the heater

on

Dirty blower assembly

Clean blower assembly

Defective blower assembly

Replace heater assembly

Grinding or excessive noise with

the heater off

Moving flame rod hitting or rubbing

against internal components

Ensure rod is straight and mounted properly in the

bracket, spinning freely away from other components.

Replace if necessary.

Defective flame motor

Replace flame motor