Leak testing – Permasteel PG-50601SRL(N) User Manual

Page 26

background image

23

ƒ

GENERAL
Although all gas connections on the grill are leak tested at the factory prior to

shipment, a complete gas tightness check must be performed at the installation site
due to possible mishandling in shipment, or excessive pressure unknowingly being
applied to the unit. Periodically check the whole system for leaks, or immediately
check if the smell of gas is detected.

ƒ

BEFORE TESTING

1) Make sure that all packing material is removed from the grill including the burner

tie-down straps.

2) Do not smoke while leak testing.
3) Never leak test with an open flame.
4) Make a soap solution with one part liquid detergent and another part water.

Prepare a spray bottle, brush, or rag to apply the solution to the connections. For
the initial leak test, make sure the cylinder is full.

5) Grill must be leak tested outdoors in a well-ventilated area, away from ignition

sources such as gas fired or electrical appliances, and flammable materials.

6) Keep grill away from open flames and/or sparks while testing.

ƒ

TO TEST GAS LEAK ON LP GAS GRILLS

1) Make sure all control knobs are in the “ OFF ” position.
2) Make sure the regulator is connected to the tank tightly.
3) Completely open tank valve by turning counter clockwise. If you hear a “POP”

sound, turn gas off IMMEDIATELY, as it indicates a heavy leak at the connection.
Call your gas dealer or fire department.

4) Check every connection from the tank up to and including the connection to

the manifold pipe assembly (the pipe that goes to the burner) by brushing or
spraying the soapy solution on the connections.

5) If soap bubbles appear, there is a leak. Turn off tank valve IMMEDIATELY

and retighten connections, open tank valve again, and recheck.

6) If leaks cannot be stopped, DO NOT ATTEMPT TO REPAIR. Call our service

center for help (888)-287-0735.

7) Always close the tank valve after leak testing by turning clockwise.

Only those parts recommended by the manufacturer should be used on the grill.
Substitution will void the warranty. Do not use the grill until all connections have
been checked and do not leak.