Troubleshooting, Cleaning and maintenance – Desa CGMFP User Manual
Page 25

www.desatech.com
119315-01A
5
LOG SET
• If you remove one-piece log set for cleaning,
refer to Installing Log Set and Screen, page 18,
for placement instructions.
• Replace log set if broken or chipped (dime-sized
or larger).
CABINET
Air Passageways
Use pressurized air to clean.
Exterior
Use a soft cloth dampened with a mild soap and
water mixture. Wipe the cabinet to remove dust.
Figure 41 - Pilot Inlet Air Hole
(Propane/LP Gas)
Pilot Assembly
Pilot Air
Inlet Hole
Pilot Assembly
Pilot Air
Inlet Hole
Figure 42 - Pilot Inlet Air Hole
(Natural Gas)
ClEaNiNG aND
MaiNTENaNCE
Continued
TRoUBlEshooTiNG
WARNING: Turn off and unplug fireplace and let cool before
servicing. Only a qualified service person should service and repair
fireplace.
CAUTION: Never use a wire, needle or similar object to clean
ODS/pilot. This can damage ODS/pilot unit.
Note:
All troubleshooting items are listed in order of operation.
POSSIbLE CAUSE
1. Ignitor electrode not con-
nected to ignitor cable
2. Ignitor cable pinched or wet
3. Broken ignitor cable
4. Bad ignitor
5. Ignitor electrode positioned
wrong
6. Ignitor electrode broken
7. Battery not installed, battery
power low or battery not
installed correctly
REMEDY
1. Reconnect ignitor cable
2. Free ignitor cable if pinched
by any metal or tubing. Keep
ignitor cable dry
3. Replace ignitor cable
4. Replace ignitor
5. Replace pilot assembly
6. Replace pilot assembly
7. Install new alkaline battery in
electronic ignitor. Verify bat-
tery is installed correctly
ObSERVED PRObLEM
When ignitor button is pressed,
there is no spark at ODS/pilot