ONICON F-5200 Insertion User Manual
Page 7
11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax (727) 442-5699 • [email protected]
F-5200 Insertion Thermal Mass Flow Meter Manual 05/14 - 0756-8 / 19475
Page 7
1.4 ADDITIONAL REQUIRED HARDWARE
All ONICON insertion thermal mass meters can be installed and removed via a ¾” or larger full
port ball valve without disrupting flow. The terms “Standard” and “Hot Tap” refer to the
installation method only.
Standard Installation: Occurs during new construction or
scheduled shutdown. Once the kit is installed, the flow meter can
be installed or removed without disrupting flow.
Hot Tap Installation: For applications which require the access
hole in the pipe to be drilled through the valve using a wet tap
drilling machine while the piping system is pressurized.
NOTE: Installation hardware materials vary based on pipe
material, pipe size, the maximum operating pressure and the
maximum operating temperature.
Contact ONICON when installation hardware is required for
different pipe materials or when higher pressure or temperature ratings are required.
Part #
Kit Description
Items Included with Kit
INSTL64
Installation kit for 1” and larger welded carbon
steel pipe
Maximum operating pressure, 50 PSIG
Maximum operating temperature, 200°F
¾” full port bronze ball valve
¾” galvanized close nipple
¾” to ½” brass reducer bushing
¾” carbon steel weld-on branch outlet
½” stainless steel compression fitting with PTFE ferrules
INSTL69
Stainless steel installation kit for 1” and larger
welded carbon steel pipe
Maximum operating pressure, 50 PSIG
Maximum operating temperature, 200°F
¾” full port SS ball valve
¾” SS close nipple
¾” to ½” SS reducer bushing
¾” carbon steel weld-on branch outlet
½” stainless steel compression fitting with PTFE ferrules
INSTL70
Installation kit for 1” and larger welded carbon
steel pipe
Maximum operating pressure, 500 PSIG
Maximum operating temperature, 140°F
¾” full port bronze ball valve
¾” galvanized close nipple (Qty 2)
¾” carbon steel weld-on branch outlet
¾” stainless steel weldment with steel cable and
retaining collars
½” stainless steel compression fitting with PTFE ferrules
INSTL91
Insertion meter compression fitting w/o
installation hardware, 125psig/140° F max
½” stainless steel compression fitting with PTFE ferrules
INSTL82
Stainless steel installation kit for 1” and larger
welded stainless steel pipe
Maximum operating pressure, 500 PSIG
Maximum operating temperature, 140° F
¾” full port SS ball valve
¾” SS close nipple (Qty 2)
¾” stainless steel weld-on branch outlet
¾” stainless steel weldment with steel cable and
retaining collars
½” stainless steel compression fitting with PTFE ferrules
Compression Fitting
Reducer Bushing
Ball Valve
Close Nipple
Weld-on Branch Outlet
(INSTL 64 Shown)