CONNECTIONS & CONTROLS
POWER SUPPLY
J1
5-Pin DIN Connector to Power Units 1 through 5. Pinout is as follows;
Pin 1
Output DC Voltage (+13 or +17 V
DC
depending on the position of S1 left switch).
Pin 2
Ground
Pin 3
Ground
Pin 4
FAULT. If this input is LOW, D1 will light.
Pin 5
Causes D3-7 to light when pulled high.
Pin 6
22kHz flag. Power supply pulls this LOW if the 22kHz tone is enabled.
Pin 7
Ground
Pin 8
Ground
Pin 9
Ground
J6
AC Input. 90-250 V
AC
, 47-63 Hz. 2.5 Amp Slo-Blo, 5x20mm fuse.
D1
Power indicator. Green when normal.
D2
FAULT Indicator. If any module connector to J1 through J5 pulls pin 4 low, this will be
RED. Otherwise it will be dark.
D3-7 Indicates if a module is connected to this position.
S1-5 The left switch is used to select the LNB voltage (+13V or +17V). The right switch is
used to turn the 22kHz tone ON or OFF.