beautypg.com

4 specifications, 1 electrical specifications – Northern Airborne Technology AMU50-001 User Manual

Page 6

background image

AMU50-001 Audio Management Unit

SM76 Installation and Operation Manual


Section 1 Rev: 1.03

Issue 1

Page 1-3

ENG-FORM: 800-0116.DOT

CONFIDENTIAL AND PROPRIETARY TO NORTHERN AIRBORNE TECHNOLOGY LTD.

In Emergency mode all ACPs are deactivated, and only User 1 and User 2 maintain a limited amount of
functionality. In this mode, User 1 will be able to listen to COM1, NAV1, Direct1, Direct2, Direct3 and all
alerts at a fixed level, and transmit on COM1. User 2 will be able to listen to COM2, NAV2, Direct1,
Direct2, Direct3 and all alerts at a fixed level, and transmit on COM2. Both User 1 and User 2 will have
keyed intercom audio at a fixed level.

Emergency mode disables the Digital Signal Processing software and provides the above functionality via
analog technology.

1.4

Specifications

1.4.1

Electrical Specifications


POWER

NORM and EMERG Power Inputs (NORM +28 VDC Power, EMERG +28 VDC Power)

Normal Operating Conditions:

Nominal input voltage

28.0 Vdc

Maximum input voltage

30.3 Vdc

Minimum input voltage

22.0 Vdc

Emergency input voltage

18.0 Vdc

Abnormal Operating Conditions:

Maximum input voltage

32.2 Vdc

Minimum input voltage

20.5 Vdc

Maximum Current:

2.6 A @ 28.0 Vdc with 6 ACPs connected and lights at maximum

Power Outputs for ACP (ACP 1 PWR thru ACP 6 PWR)

Quantity: Six

Output Voltage:

25.5 Vdc (Nominal) with a +28.0 Vdc input to the AMU50

Maximum Current:

0.25A @ 25.5 Vdc

Power Output for RM01 (RM01 PWR)

Quantity: One

Output Voltage:

5 Vdc ±10% (Nominal)

Maximum Current:

0.10 A @ 5 Vdc

INPUTS

Audio Inputs

MIC Inputs

Three microphone impedances available: User 1 and User 2 microphone impedances must be
the same; User 3 through User 7 microphone impedances are independently configurable.

Quantity

Seven, configured through DevCs application.

Gain

Independently adjustable from -9 dB to +6 dB of nominal input

level, +/- 1dB with 15 steps of adjustment