beautypg.com

Operation, 1 introduction, 2 general information – Northern Airborne Technology AMU50-001 User Manual

Page 37: 3 control functionality, 1 audio control panels, 2 ptt keys

background image

AMU50-001 Audio Management Unit

Installation and Operation Manual


Section 3 Rev: 1.00

Issue 1

Page 3-1

ENG-FORM: 806-0113.DOT

CONFIDENTIAL AND PROPRIETARY TO NORTHERN AIRBORNE TECHNOLOGY LTD.

Section 3 Operation

3.1

Introduction

Information in this section consists of the functional and operational procedures for the AMU50-001 Audio

Management Unit (AMU50).

The AMU50 Audio Management Unit has no operator accessible controls.

If the AMU50 is part of the Northern Airborne Technology Ltd Digital Audio Communications System

(DACS), all modifications to the operating parameters are made through the Device Configuration

Software (DevCs). For full information, consult the DevCs manual.

The AMU50 controls the functionality of all the components of an aircraft's communications system,

including, but not limited to, the Audio Control Panels (ACPs) and external switches. The general

functionality of these components is outlined in section 3.3 below.

3.2

General Information

The AMU50 Audio Management Unit is part of the Digital Audio Communication System (DACS), a

management system that distributes and controls all of the transceiver, receiver and warning source

audio in an aircraft. It enables the transmission of microphone audio to a selected Transceiver and

distributes all Inter-Communication System (ICS) audio.

The primary component of the DACS is the AMU50. Connected to this Line Replaceable Unit (LRU) are

the user headsets, transceivers, receivers, and the ACPs. The AMU50 also has an audio accessory port

that enables the connection of a unit for providing ICS audio in the cabin.

3.3

Control Functionality

The AMU50 can be configured to control the functionality of any ACPs and a variety of external switches

and indicators that are connected into the system.

Note: Confirm the specific criteria associated with this installation with your installing agency.

3.3.1

Audio Control Panels

The Audio Control Panels are the operator interface with the AMU and the digital audio communications

system. For information on the operation of the ACP, refer to the relevant Installation and Operation

Manual (for example SM75, the ACP53-001 Audio Control Panel Service Manual.)

All the operational and functional criteria for ACPs installed in a DACS are controlled by the AMU50 and

configured through the DevCs. For full information, consult the DevCs manual.

3.3.2

PTT Keys

The AMU50 supports six TX PTT and seven ICS PTT keys.