Discrete Outputs

All the following outputs have these specifications unless stated otherwise.

Logic:

Active LO, switched ground

Output Active:

≤2

Current:

1 A maximum

Transmit Push-To-Talk Outputs

Quantity: Eight

Crew Isolation Output (CREW ISO OUT)

Quantity: One

Aural Alert Active Output (ALERT ACTIVE)

Quantity: One

DF Blanking Output (DF BLANKING OUTPUT)

Quantity: One

Emergency Mode Active Output (EMERG/BACKUP OUT)

Quantity: One

BI-DIRECTIONAL PORTS

USB Port

Quantity:

One USB 2.0 (for programming)

ICS Tieline
The ICS tie line can be configured (using DevCs) for analog or digital operation.

Analog:

Quantity: One

Output Impedance: 2000

Ω +/-10%

Rated Level:

230 mVrms into 1000 ohms +/-15%

Circuitry Type:

Balanced

Digital:

Quantity: One

Specification: RS422
Serial Data Protocol: SP/DIF

1.4.1.1

Audio Performance


The AMU50 meets the requirements of FAA TSO-C139, EASA ETSO-C50c and RTCA/DO-214 Class Ib.

Audio Frequency Response:

<3dB from 300 - 6000Hz


Volume Controls:

40dB of adjustment (individual receive audio and intercom audio)

30dB of adjustment (master receive audio)