beautypg.com

Northern Airborne Technology NTX User Manual

Page 36

background image

NTX138 Installation Approval Test Procedure

Page 2 of 7

Aug 31, 2001

Rev. 1.00

E NG-FORM: 634-0100.DOT

CONFIDENTIAL AND PROPRIETARY TO NORTHERN AIRBORNE TECHNOLOGY LTD.

4. Results

If the installed system passes all of the applicable EMI tests, then no further action is
required. If interference is observed, then the interference must be assessed against
the appropriate standards of airworthiness for the system in question. For example: it is
permissible for a VFR certified GPS to lose navigation capability while the NTX138 is
transmitting, providing that it recovers properly and promptly, but it is not permissible for
an IFR Approach certified GPS to be affected in the same way. A complete discussion
of all the standards of airworthiness to be applied in assessing EMI effects is beyond
the scope of this document.

5. Procedure

A.

Operate the NTX138 transmitter on the following frequencies for at least 20 seconds.
Observe the GPS for any degradation in satellite status, or availability, or flags.

FREQUENCIES

GPS #1

GPS #2

NTX138 PASS

FAIL

PASS

FAIL

143.180

MHz

143.1825

MHz

157.5000

MHz

157.5425

MHz


NOTES: