4 jumper jp101, 5 final checks, 7 accessories required but not supplied – Northern Airborne Technology CC250 User Manual
Page 18

CC450-0V2 Communications Controller
Installation and Operation Manual
2.6.4
Jumper JP101
Jumper JP101
Position
1-2 Normal
Position
For correct operation, this jumper must be in the
1-2 position. This diagram is included to ensure
that the installer can replace the jumper if it is
accidentally dislodged.
2.6.5 Final
Checks
If any preset requires adjustment, be sure this is carried out before the aircraft leaves, and that the unit
and its mating connector are secured before departure. Make all required log book entries, electrical
load, weight and balance amendments and other paperwork as required by your local regulatory agency.
2.7
Accessories Required But Not Supplied
The CC450-IKC kit consists of one D15SL-IKC, one D37SL-IKC, and one CC450-DMY. The contents of
each of these kits are listed below.
NAT Part #: D15SL-IKC consists of:
Quantity
Description
NAT Part #
1
D-min 15 Socket Housing
20-21-015
15
MS Crimp Socket
20-26-901
1*
Jack Screw Set
20-27-002
1*
Lock Clip Set
20-27-004
1
15 Pin Connector Hood
20-29-015
NAT Part #: D37SL-IKC consists of:
Quantity
Description
NAT Part #
1
D-min 37 Socket Housing
20-21-037
37
MS Crimp Socket
20-26-901
1*
Jack Screw Set
20-27-002
1*
Lock Clip Set
20-27-004
1
37 Pin Connector Hood
20-29-038
NAT Part #: CC450-DMY is a fully assembled Dummy Load that allows operation to continue if the
CC450-0V2 is removed for service. It consists of:
Quantity
Description
NAT Part #
1
D-sub plug, Solder cup
20-10-037
1
Hood, D-sub, plastic
20-29-038
1*
Jack Screw Set
20-27-002
* Use as required.
Page 2-8
Issue 1
Section 2 Rev: 1.00
ENG-FORM: 805-0114.DOT
CONFIDENTIAL AND PROPRIETARY TO NORTHERN AIRBORNE TECHNOLOGY LTD.