8 maintenance every 600 hours, Periodic inspection/maintenance – MMD Equipment 25S-3A3 User Manual
Page 53

6. Periodic Inspection/Maintenance
6-11
6.7.4 Change Filter of Fuel Air-bleeding Electromagnetic Pump (SDG45S /60S )
Turn the cap counterclockwise to remove it, change
the filter inside.
As the fuel inside spills out when it is removed,
prepare a container to catch fuel.
6.8 Maintenance Every 600 Hours
6.8.1 Change Fuel Filter (SDG75S/100S)
(Procedures)
①
Loosen the center bolt, remove the filter body
and element together.
②
After cleaning the filter body, insert a new
element into it and fasten it by the center bolt.
③
Bleed the air of fuel.(See 5.5)
④
After assembling a fuel filter, check for fuel
leakage during operation.
6.8.2 Change Filter of Fuel Air-bleeding Electromagenetic Pump
(SDG75S/100S)
Follow the same procedure for changing filter of fuel Air-bleeding electromagnetic pump as
mentioned in 6.7.4.
TR0335
SG0412
TR0335
Cap
Filter
Center bolt
Filter body
Drain plug
Part No. :
Isuzu Motors genuine
894337 0220
Part No. :
Isuzu Motors genuine
988511-1911