Section 1 technical information, Section 2 electrical information, Section 3 mechanical information – MK Products CobraCooler 1999 User Manual
Page 9: Section 4 power tapping
Owner’s Manual - Page 9
Section 1
TECHNICAL INFORMATION
Line Power: 100, 120, 200 230VAC 50/60 HZ, Single Phase ONLY
Reservoir Capacity: 2 qt. / 1.8 l
Coolant Type & Ratio: 3 parts distilled water : 1 part ethylene glycol : 1
tablespoon liquid glycerin
Flow Rate: 0.21 qt/min. / 0.2 l/min. minimum
Section 2
ELECTRICAL INFORMATION
Pump: 120VAC, 50/60 Hz, 0.50 amps
Input Power Transformer: Auto Transformer, 100 VA
Input Taps: 100, 120, 200, 230VAC 50/60 Hz
Printed Circuit Board: Coolant fault logic, tachometer feedback
conditioning, home switch logic
AC Power for Cooling Unit: Front panel switchable, power-on LED, front
panel fuse holder
Front Panel Indicators: Power-on: LED, red; Coolant Fault: LED, red &
sonic alert
Section 3
MECHANICAL INFORMATION
Dry Weight: 21 lbs. / 9.5 Kg
Height: 5.5 in. / 14.0 cm
Width: 8.5 in. / 21.6 cm
Depth: 19 in. / 48.3 cm
Heat Exchanger: Fin and Tube, Aluminum
Pump: Gear Mesh Pump
Cooling Fans: 105 scfm / 3 std. cu. m/min., 2 each
WARNINGS:
Read and follow instructions prior to performing setup functions.
CAUTIONS:
Read and follow instructions prior to performing operational
functions.
Section 4
POWER TAPPING
WARNING
DISCONNECT UNIT FROM ALL POWER SOURCES PRIOR
TO CHANGING POWER TAPS.
ELECTRIC SHOCK CAN KILL
From the top of the CobraCooler™, open the access panel towards the rear
of the unit. Looking down into the unit, locate the power tapping terminal
strip.
Move the jumper and affix to the required input power tap setting.
Change the plug on the end of the cable to suite the required in put power
type.