beautypg.com

Section 1 technical information, Section 2 electrical information, Section 3 mechanical information – MK Products CobraCooler 1999 User Manual

Page 9: Section 4 power tapping

background image

Owner’s Manual - Page 9

Section 1

TECHNICAL INFORMATION

Line Power: 100, 120, 200 230VAC 50/60 HZ, Single Phase ONLY

Reservoir Capacity: 2 qt. / 1.8 l

Coolant Type & Ratio: 3 parts distilled water : 1 part ethylene glycol : 1

tablespoon liquid glycerin

Flow Rate: 0.21 qt/min. / 0.2 l/min. minimum

Section 2

ELECTRICAL INFORMATION

Pump: 120VAC, 50/60 Hz, 0.50 amps

Input Power Transformer: Auto Transformer, 100 VA

Input Taps: 100, 120, 200, 230VAC 50/60 Hz

Printed Circuit Board: Coolant fault logic, tachometer feedback

conditioning, home switch logic

AC Power for Cooling Unit: Front panel switchable, power-on LED, front

panel fuse holder

Front Panel Indicators: Power-on: LED, red; Coolant Fault: LED, red &

sonic alert

Section 3

MECHANICAL INFORMATION

Dry Weight: 21 lbs. / 9.5 Kg

Height: 5.5 in. / 14.0 cm

Width: 8.5 in. / 21.6 cm

Depth: 19 in. / 48.3 cm

Heat Exchanger: Fin and Tube, Aluminum

Pump: Gear Mesh Pump

Cooling Fans: 105 scfm / 3 std. cu. m/min., 2 each

WARNINGS:

Read and follow instructions prior to performing setup functions.

CAUTIONS:

Read and follow instructions prior to performing operational

functions.

Section 4

POWER TAPPING

WARNING

DISCONNECT UNIT FROM ALL POWER SOURCES PRIOR

TO CHANGING POWER TAPS.

ELECTRIC SHOCK CAN KILL

From the top of the CobraCooler™, open the access panel towards the rear
of the unit. Looking down into the unit, locate the power tapping terminal
strip.

Move the jumper and affix to the required input power tap setting.

Change the plug on the end of the cable to suite the required in put power
type.