beautypg.com

Technical specifications, Support equipment required, Coolant requirements – MK Products Cobra MX User Manual

Page 8: Gun lead connections

background image

Cobra

®

MX Euro Compatible™ 7 Pin Owner's Manual - Page 1

Section A

Installation

Technical Specifications

Wire Capacity
.030" - .045" (0.8mm - 1.2mm) solid hard wire, and cored wire
.030" - 1/16" (0.8mm - 1.6mm) aluminum

Wire Speed
800 IPM (20.3 mpm) max
Duty Cycle - 60%
All ratings are using Argon gas
175 Amps/25 Volts

Air Cooled, 1/4" Tip (Model 298)

200 Amps/25 Volts

Air Cooled, 3/8" Tip (Model 300)

225 Amps/25 Volts

Water Cooled, 1/4" Tip (Model 299)

250 Amps/25 Volts

Water Cooled, 3/8" Tip (Model 301)

Support Equipment required

C.V. or C.C. power source of sufficient capacity for your needs.

• Regulated gas supply and hoses.

• Properly sized power leads from power source to wire feeder and

ground.

• Water source and hose capable of providing a minimum of

1 quart

(.95 liter) / min. at 45 p.s.i. when using water cooled guns.

Coolant requirements

WARNING: Use only Cobra Coolant - failure to use coolant will void
warranty.

Use Cobra Coolant (Aluminum Protection),which does not contain reactive
sulphur or chlorine and does not react with copper, brass or aluminum. The
Cobra Coolant is available in quantities of 1 gallon (P/N 931-0060), 5 gallon
(P/N 931-0060-5GAL), or a case of 4 gallons each (P/N 931-0060-4).
The coolant flow rate should be a minimum of 10 GPH (1 qt/min) between

35 and 45psi. Contact the re-circulator manufacturer for specifications on
pressure.

Gun Lead Connections

Power Cable - Air Cooled

A #2 power cable is used on the Cobra MX Euro Compatible 7 Pin

gun. The

gun and Euro Power Manifold ends of the cable are stripped to the copper
strands and wrapped with a copper strip. A setscrew holds the cable securely
in the gun body and in the Euro Power Manifold with torque requirements of
55-60 in-lb.

Power Cable - Water Cooled

The Cobra MX Euro Compatible 7 Pin

water cooled gun utilizes a power/

water cable with a #6 AWG cable inside a 5/16” diameter hose.
The power cable ends are threaded fittings which screw into the gun body
and the Euro Power Manifold. These connections utilize a conductive sealant
and are tightened with torque requirements of 100 + 5 IN-LB.

Conduit

The Cobra MX Euro Compatible 7 Pin

gun comes standard with a poly-

lined conduit, for feeding aluminum wire. The longer fitting with a shallow
groove is used on the gun end. A set screw located on top of the gun handle
secures the conduit in place. The cabinet end of the conduit is secured into
the Euro Power Manifold with a set screw.

Gas Hose

The BLACK gas hose is pushed over a barbed fitting on the end of the gun
body and secured by twisting the hose retainer to the end of the hose (shown
next page). The opposite end of the BLACK hose is pushed over a barbed

fitting in the Euro Power Manifold. The hose retainer is re-usable and can be
removed and re-installed as needed.