Dip-switch – Microsens MS655099 User Manual

Page 14

background image

10

DIP-Switch

The DIP-Switch is used to configure operation mode for LLF (Link Lost

Forwarding) and power alarm. The default value of DIP-switch is OFF.

Table 2.2: Industrial Switch Converter DIP-Switch Definition

S/W No

Status

Description

1

ON

Enable Power Alarm

OFF

Disable Power Alarm

2

ON

Enables LLF

OFF

Disables LLF

Link Lost Forwarding (DIP-Switch 2): When LLF is enabled, it allows

UTP link failures to be reported to the fiber side and also allows Fiber

link failures to be reported to the UTP side. Therefore, a link loss

forwarding feature is provided in both UTP and Fiber side.

Note

When SW 2 is on, once the fiber or UTP/STP cable is

disconnected, the LNK/ACT LED off. When the cable is

reconnected, the LNK/ACT LED blinks for 2 ~ 6 seconds which

means the connection is recovering from failure.

Note

Please don’t change the DIP-switch setting when UTP/STP or

fiber port is transmitting or receiving data. It may cause some data

error. Besides, if you change the DIP-switch setting, please power

off the converter and power on again to make the setting effective.