Dip-switch – Microsens MS655020X User Manual
Page 5

Ethernet VDSL2 Extender - manual
Page 5/9
MICROSENS GmbH & Co. KG - Kueferstraße 16 - 59067 Hamm / Germany - Tel. +49 23 81/94 52-0 - FAX -100 - www.microsens.com
ON
Link up
OFF
Link down
LNK/ACT for LAN
(Green)
BLK
Transmitting
ON
100Mbps
OFF
10Mbps
Speed for LAN
(Amber)
BLK
---
ON
Acting as Customer Premise
Equipment (CPE) side
OFF
Acting as Central Office (CO) side
CO (Green)
BLK
---
ON
Link up
OFF
Link down
LNK/ACT for VDSL
(Green)
BLK
Negotiating, Transmitting
DIP-switch
The DIP-switch is used to configure operation mode in below. The default value of
Dipswitch is OFF.
S/W
No
Feature
Status
Description
ON
Acting as Customer Premise Equipment (CPE)
side
1
Master, Slave
switch
OFF
Acting as Central Office (CO) side
ON
Fast mode: Direct data transmission with
latency less than 1ms.
2
Impulse noise
protection
OFF
Interleave mode: Provides communication
protection for up to 250ms impulse noise
latency less than 6ms.
ON
Limit line-rate Disable: Provides up to
100Mbps/60Mbps line rate in short line.
3
Rate limit
control
OFF
Limit line-rate Enable: Line rate limited to 50/20
Mbps.
ON
SNR 6dB: Original and Normal channel noise
protection with 6dB SNR.
4
General
protection
OFF
SNR 9dB: Higher SNR margin (9dB) will result in
less error with more stable VDSL link.
Note:
Please set DIP4 OFF when operating in harden environment. That mean will keep better
performance.