beautypg.com

Led indicators – Microsens MS655060-562P User Manual

Page 8

background image

5

LED Indicators

The diagnostic LEDs located on the front panel of the industrial switch provide real-time

information of system and optional status. The following table provides the description of

the LED status and their meanings for the switch.

LED

Color

Description

P1

Green

On

Power input 1 is active

Off

Power input 1 is inactive

P2

Green

On

Power input 2 is active

Off

Power input 2 is inactive

Fault

Red

On

Power input 1/2 or port connections failed

Off

Power input 1/2 and port connections are functional, or

no power inputs

FDX/COL

(fiber port)

Yellow

On

Full-duplex mode

Flashing

Collision occurs

LNK/ACT

(fiber port)

Green

On

Connected to network

Flashing

Networking is active

Off

Not connected to network

100M (RJ-45)

Yellow

On

Linking to 100Mbps network

Off

Linking to 10Mbps network or disconnected

LNK/ACT (RJ-

45)

Green

On

Connected to network

Flashing

Networking is active

Off

Not connected to network

FWD

Green

On

The port is supplying power to the powered-device

Off

No powered-device attached or power supplying fails

This manual is related to the following products: