Troubleshooting

 Verify that is using the right power cord/adapter (DC 48V), please don’t use the

power adapter with DC output voltage higher than 48V, or it will burn this converter

down.

 Select the proper UTP/STP cable to construct your network. Please check that is

using the right cable. Use unshielded twisted-pair (UTP) or shield twisted-pair

( STP ) cable for RJ-45 connections: 100Ω Category 3, 4 or 5 cable for 10Mbps

connections, 100Ω Category 5 cable for 100Mbps connections, or 100Ω Category

5e/above cable for 1000Mbps. Also be sure that the length of any twisted-pair

connection does not exceed 100 meters (328 feet).

Diagnosing LED Indicators: the Switch can be easily monitored through panel

indicators, which describes common problems user may encounter and where user

can find possible solutions, to assist in identifying problems.

 If the power indicator does not light on when the power cord is plugged in, user may

have a problem with power cord. Then check for loose power connections, power

losses or surges at power outlet. If you still cannot resolve the problem, contact the

local dealer for assistance.

 If the Industrial switch LED indicators are normal and the connected cables are

correct but the packets still cannot transmit. Please check your system’s Ethernet

devices’ configuration or status.