III. CLEANING INSTRUCTIONS
CAUTION
AT NO TIME SHOULD THE MODULE OR
CABINET BE WASHED OR FLOODED WITH
WATER OR LIQUID SOLUTION. NEVER
STEAM CLEAN. SEVERE DAMAGE OR
ELECTRICAL HAZARD COULD RESULT.
1. Turn off power switch.
2. Unplug the unit from its power source.
WARNING
ALLOW THE UNIT TO COOL BEFORE
CLEANING, AS THE INTERIOR OF THE
CABINET MAY BE HOT ENOUGH TO BURN.
A. SHELF REMOVAL/INSTALLATION
To remove the shelves, all shelves must first
be lowered onto the bottom shelf. Start with
the shelf above the bottom shelf by lifting it off
of the shelf hangers and by lowering the front
edge and raising the rear edge so that it can
be lowered onto the bottom shelf. Repeat the
procedure until all of the shelves are on the
stack on the bottom shelf.
On double door cabinets, lift the uppermost
shelf off of the stack so that you are holding
onto the long edge of the shelf and the shelf
is hanging vertically. Position the shelf so one
vertical edge is in one of the rear cabinet
corners. Swing the other vertical edge out the
door and remove the shelf. Repeat until all the
shelves are removed.
On single door cabinets, lift each shelf off of
the stack so that you are holding onto the long
edge of the shelf and the shelf is hanging
vertically. Position the shelf so that one vertical
edge is in one of the rear cabinet corners and
the other vertical edge is towards the diagonal
front corner. Depending on the model of the
one door cabinet, the shelf may have to be
rotated towards a vertical position to remove it
from the cabinet.
To install the shelves, reverse the above
procedure. Before installing the shelves
install the module (Section B below) and, if so
equipped, the Quad-Heat Fuel System baffle(s)
and chimney(s) (Section C below).
NOTE: The shelf wires that run from left to right
in the cabinet should be on the top side of the
installed shelves. Make sure the shelves are
seated in the hangers correctly.
On single door MBQ-90 and 72 cabinets, the
shelves have two 90° square corners and two
45° notched corners. The 45° corners go to the
right end as you look into the cabinet.
B. ELECTRIC HEATING MODULE
REMOVAL /INSTALLATION
1. Remove the module from the cabinet by
lifting and sliding the module rearward. Lift
the front of the module and stand it vertically
C. TIMER
TO SET THE TIMER:
1. Press ‘MIN’ button to set minutes.
2. Press ‘SEC’ button to set seconds.
3. Press ‘START/STOP’ to start timer.
4. To pause the timer, pless ‘START/STOP’.
Press again to restart countdown.
5. When alarm beeps, press ‘START/STOP’ to
turn off alarm. The timer will recall the last set
time.
6. Press ‘RESET’ to return display to 00:00”.
7. The timer will also count up. Press START/
STOP’ when the display reads 00:00” and the
timer will count up.
8. The timer will time up to 99 minutes and 59
seconds.
9. To attach using the magnets on the back of
the timer, gently slide the clip out of the timer
casing. To replace the clip, slide it back into
the groove.