Description of IRIG-Codes

The specification of individual IRIG time code formats is defined in IRIG Standard
200-98. They are described by an alphabetical character followed by a three-digit
number sequence. The following identification is taken from the IRIG Standard 200-
98 (only the codes relevant to TCR170PEX are listed):

character

bit rate designation

A

1000 pps

B

100 pps

1st digit

form designation

0

DC Level Shift
width coded

1

sine wave carrier
amplitude modulated

2nd digit

carrier resolution

0

no carrier (DC Level Shift)

1

100 Hz, 10 msec resolution

2

1 kHz, 1 msec resolution

3

10 kHz, 100

μsec resolution

3rd digit

coded expressions

0

BCD, CF, SBS

1

BCD, CF

2

BCD

3

BCD, SBS

BCD:

time of year, BCD-coded

CF:

Control-Functions (user defined)

SBS:

seconds of day since midnight (binary)