Technical specifications – Meinberg VP100 20 User Manual
Page 16

16
Technical Specifications:
OPERATION
MODE:
- as free running quartz clock with internal RTC
- as slave clock synchronized by radio clock or master clock
with serial time strings or pulses per minute
- as radio clock with integrated DCF77 receiver
DISPLAY:
LED Dot Matrix Display (120 x 7 dots, 915mm x 55mm)
INPUTS:
RS232 or 20mA current loop (passive/active) or pulses per
minute (pulse voltage: 48V max.);
D-SUB25 connector
OUTPUTS:
RS232 or 20mA current loop (passive/active) or pulses per
minute (pulse voltage: as applied to input);
D-SUB25 connector
BAUDRATE:
9600 baud
FRAMING:
7E2
TIME STRING:
see "Format of the Meinberg Standard Time String"
BUFFERING:
In case of supply voltage failure the on-board RTC keeps the
time based on XTAL for more than 10 years.
POWER
REQUIREMENTS: 85-264VAC, 50/60Hz / 120-375VDC, approx. 40VA
FUSE:
0,5A(T)
PHYSICAL
DIMENSION:
1000mm x 100mm x 60mm
WEIGHT: