beautypg.com

Technical specifications – Meinberg VP100 20 User Manual

Page 16

background image

16

Technical Specifications:

OPERATION
MODE:

- as free running quartz clock with internal RTC
- as slave clock synchronized by radio clock or master clock
with serial time strings or pulses per minute
- as radio clock with integrated DCF77 receiver

DISPLAY:

LED Dot Matrix Display (120 x 7 dots, 915mm x 55mm)

INPUTS:

RS232 or 20mA current loop (passive/active) or pulses per
minute (pulse voltage: 48V max.);
D-SUB25 connector

OUTPUTS:

RS232 or 20mA current loop (passive/active) or pulses per
minute (pulse voltage: as applied to input);
D-SUB25 connector

BAUDRATE:

9600 baud

FRAMING:

7E2

TIME STRING:

see "Format of the Meinberg Standard Time String"

BUFFERING:

In case of supply voltage failure the on-board RTC keeps the
time based on XTAL for more than 10 years.

POWER
REQUIREMENTS: 85-264VAC, 50/60Hz / 120-375VDC, approx. 40VA

FUSE:

0,5A(T)

PHYSICAL
DIMENSION:

1000mm x 100mm x 60mm

WEIGHT:

5,2kg