IbcAUTOPOLL

bd

Enable/Disable Automatic Serial Polling. If

value

is 0,

then Automatic Serial Polling is disabled. Otherwise, it
is enabled.

IbcCICPROT

bd

CIC Protocol. If value is 0, then CIC Protocol is not
used. Otherwise, CIC Protocol is used.

IbcIRQ

bd

Enable/Disable Hardware Interrupts. If

value

is 0, then

hardware interrupts are disabled, otherwise

value

specifies the IRQ level the board uses to generate
interrupts.

IbcSC

bd

Request/Release System Control. If

value

is 0, the

board is not able to support routines requiring system
controller capability.

If

value

is non-zero, the board can support routines

requiring system controller capability.

IbcSRE

bd

Assert/Unassert REN. If

value

is 0, the REN line is

unasserted. Otherwise, the REN line is asserted.

IbcEOSrd

bd or dev

Recognize EOS. If

value

is non-zero, a read is

terminated when the End-Of-String (EOS) character is
detected. Otherwise, EOS detection is disabled.

IbcEOSwrt

bd or dev

Assert EOI. If

value

is non-zero, then EOI is asserted

when the EOS character is sent. Otherwise, EOI is not
asserted.

IbcEOScmp

bd or dev

7/8-bit Comparison. If

value

is zero, compare the

low-order 7 bits of the EOS character. Otherwise,
compare 8-bits.

IbcEOSchar

bd or dev

End-Of-String (EOS) Character.

value

is the new EOS

character.

value

can be any 8-bit value.

IbcPP2

Parallel Poll Remote/Local. If

value

is zero, then the

GPIB Interface Board is remotely configured for a
parallel poll by an external Controller. Otherwise, the
GPIB interface board accepts parallel poll configuration
commands from your application program.

Table 3-3. ibconfig Options (Continued)

Option

Valid for

Description