Chapter 3
GPIB 488.1 Library Reference
3-12
GPIB-488
IbcAUTOPOLL
bd
Enable/Disable Automatic Serial Polling. If
value
is 0,
then Automatic Serial Polling is disabled. Otherwise, it
is enabled.
IbcCICPROT
bd
CIC Protocol. If value is 0, then CIC Protocol is not
used. Otherwise, CIC Protocol is used.
IbcIRQ
bd
Enable/Disable Hardware Interrupts. If
value
is 0, then
hardware interrupts are disabled, otherwise
value
specifies the IRQ level the board uses to generate
interrupts.
IbcSC
bd
Request/Release System Control. If
value
is 0, the
board is not able to support routines requiring system
controller capability.
If
value
is non-zero, the board can support routines
requiring system controller capability.
IbcSRE
bd
Assert/Unassert REN. If
value
is 0, the REN line is
unasserted. Otherwise, the REN line is asserted.
IbcEOSrd
bd or dev
Recognize EOS. If
value
is non-zero, a read is
terminated when the End-Of-String (EOS) character is
detected. Otherwise, EOS detection is disabled.
IbcEOSwrt
bd or dev
Assert EOI. If
value
is non-zero, then EOI is asserted
when the EOS character is sent. Otherwise, EOI is not
asserted.
IbcEOScmp
bd or dev
7/8-bit Comparison. If
value
is zero, compare the
low-order 7 bits of the EOS character. Otherwise,
compare 8-bits.
IbcEOSchar
bd or dev
End-Of-String (EOS) Character.
value
is the new EOS
character.
value
can be any 8-bit value.
IbcPP2
Parallel Poll Remote/Local. If
value
is zero, then the
GPIB Interface Board is remotely configured for a
parallel poll by an external Controller. Otherwise, the
GPIB interface board accepts parallel poll configuration
commands from your application program.
Table 3-3. ibconfig Options (Continued)
Option
Valid for
Description