beautypg.com

Measurement Computing ChartScan/1400 Quick Start User Manual

Chartscan/1400 quick start, Before you get started

background image

483-0940

rev

6.0

324601C-01

ChartScan/1400 Quick Start

Portable Data Recorder

Before you get started

verify that you have the following items.

ChartScan/1400

Data Acquisition CD (8.1.2 or higher)

Monitor: SVGA, 1024 x 768 screen resolution

Windows 2000 SP4 and Windows XP users:

PC with Intel

Pentium [or equivalent]; 1 GHz

512 MB memory; 10 GB disk space

Windows Vista users:

PC must be Windows Vista Premium Ready

Step 1 - Install Software

IMPORTANT ! Software must be installed first!

1. Close all running applications on the host PC.
2. Insert the Data Acquisition CD (8.1.2 or higher) into your CD-ROM drive and wait for the PC to auto-run. An Opening Screen

will appear. If AutoRun is disabled: (a) right click Windows Start menu, (b) select Explore; and (c) double-click MasterSetup.exe.

As an alternative to using the CD, you can download software from:

www.iotech.com/ftp.html

3. Click the <ENTER SETUP> button.

Note: If you are downloading software from our website, follow instructions provided there.

4. From the hardware selection screen [which follows a licensing agreement], select the ChartScan/1400; then follow the on-screen

instructions.

NOTE

: To enable all ChartView features: (a) From ChartView’s main window, open the File pull-down menu, (b) select Author-

ization, (c) enter

C3523DFA6C0A

in the dialog box and apply the code.

Step 2 – Check Hardware

1. Verify that the voltage stated on the sticker [near the power switch] matches the voltage of

your intended AC power supply. If you need to change the voltage, refer to your user’s

manual.

2. Check the DIP switch, located on the rear panel. It should match the default setting as

indicated in the figure. Your user’s manual discusses setting options.

3. Signal conditioning cards are pre-installed at the factory. However,

if you need to remove or install a card, refer to your user’s manual.

Step 3 - Connect to the Host PC & Apply Power

ChartScan/1400 is pre-configured for serial port connection to the host PC. For IEEE 488 connection refer to the Hardware Installation section

of your user’s manual.

For USB connection refer to the associated Quick Start document (QS RS-232_to_USB_Interface.pdf). The pdf is

included on your Data Acquisition CD (rev 8.1.2 and higher). A RS-232 to USB Interface Adapter Kit p/n CA-232-USB-KIT (available from

IOtech) is required for USB connection.
Use a CA-47 cable (or equivalent) to connect the unit to your computer. The ChartScan-end of the CA-47 cable has a DB-9 connector. The

computer end has 2 connectors (DB9 and DB25). Other crossover-type cables can be used if wired as shown in the following figure.

Recommended DIP Switch Configuration