3.2.1 ON & OFF for FORM C RELAYS

O

On means that FORM C relay common is in contact with the Normally-Open
(NO) contact.

O

Off means that FORM C relay common is in contact with the
Normally-Closed (NC) contact.

3.2.2 ON & OFF FOR FORM A RELAYS

O

On means that FORM A relay common is in contact with the Normally-Open
(NO) contact.

O

Off means that FORM A relay common is open.

3.3 INPUT REGISTER

The isolated input register is located at

BASE

address + 1.

WRITE = NO FUNCTION

READ = STATUS: Read the status of the isolated inputs. A one in the input bit
position indicates that a voltage is present at the input.

INPUT #

7

6

5

4

3

2

1

0

BIT No.

7

6

5

4

3

2

1

0

HEX

80

40

20

10

8

4

2

1

DECIMAL

128

64

32

16

8

4

2

1

7