beautypg.com

Pinout – main i/o connector, Cabling, Field wiring, signal termination, and conditioning – Measurement Computing CIO-DAS48-PGA User Manual

Page 12

background image

CIO-DAS48-PGA User's Guide

Installing the CIO-DAS48-PGA

12

Pinout

– main I/O connector

The CIO-DAS48-PGA I/O connector is a standard 50-pin header connector that is accessible from the rear of
the computer through the expansion backplate.

LLGND

50

CH 47 IN

48

CH 46 IN

46

CH 45 IN

44

CH 44 IN

42

CH 43 IN

40

CH 42 IN

38

CH 41 IN

36

CH 40 IN

34

CH 39 IN

32

CH 38 IN

30

CH 37 IN

28

CH 36 IN

26

CH 35 IN

24

CH 34 IN

22

CH 33 IN

20

CH 32 IN

18

CH 31 IN

16

CH 30 IN

14

CH 29 IN

12

CH 28 IN

10

CH 27 IN

8

CH 26 IN

6

CH 25 IN

4

CH 24 IN

2

49

LLGND

47

CH 23 IN

45

CH 22 IN

43

CH 21 IN

41

CH 20 IN

39

CH 19 IN

37

CH 18 IN

35

CH 17 IN

33

CH 16 IN

31

CH 15 IN

29

CH 14 IN

27

CH 13 IN

25

CH 12 IN

23

CH 11 IN

21

CH 10 IN

19

CH 9 IN

17

CH 8 IN

15

CH 7 IN

13

CH 6 IN

11

CH 5 IN

9

CH 4 IN

7

CH 3 IN

5

CH 2 IN

3

CH 1 IN

1

CH 0 IN

Single-ended mode

LLGND

50

CH 23 IN LO

48

CH 22 IN LO

46

CH 21 IN LO

44

CH 20 IN LO

42

CH 19 IN LO

40

CH 18 IN LO

38

CH 17 IN LO

36

CH 16 IN LO

34

CH 15 IN LO

32

CH 14 IN LO

30
28
26
24
22
20
18
16
14
12
10

8
6
4
2

CH 13 IN LO
CH 12 IN LO

CH 11 IN LO

CH 10 IN LO

CH 9 IN LO
CH 8 IN LO
CH 7 IN LO
CH 6 IN LO
CH 5 IN LO
CH 4 IN LO
CH 3 IN LO
CH 2 IN LO
CH 1 IN LO
CH 0 IN LO

49

LLGND

47

CH 23 IN HI

45

CH 22 IN

43

CH 21 IN

41

CH 20 IN

39

CH 19 IN

37

CH 18 IN

35

CH 17 IN

33

CH 16 IN

31

CH 15 IN

29

CH 14 IN

27

CH 13 IN

25

CH 12 IN

23

CH 11 IN

21

CH 10 IN

19

CH 9 IN

17

CH 8 IN

15

CH 7 IN

13

CH 6 IN

11

CH 5 IN

9

CH 4 IN

7

CH 3 IN

5

CH 2 IN

3

CH 1 IN

1

CH 0 IN

HI
HI
HI
HI
HI
HI
HI
HI
HI
HI
HI

HI

HI

HI
HI
HI
HI
HI
HI
HI
HI
HI
HI

Differential mode

Figure 5. I/O connector pin-out

Current connections are made between CH# HI and CH# LOW. The positive terminal of the current to be
measured must be connected to CH# HI (refer to Current loop measurements on page 13).

Cabling

The red stripe

identifies pin # 1

50-pin Female
IDC connector

50-pin Female

IDC Connector

1

2

49

50

2

50

1

49

Figure 2-1. C50FF-x cable

Field wiring, signal termination, and conditioning

You can use the following cabling, screw termination, and signal conditioning products with the CIO-DAS48-
PGA.

 CIO-MINI50 – 50-pin screw terminal board
 CIO-SPADE50 — 16" X 4" termination panel which mates with both 37-pin and 50-pin connectors.