N o .
Possible Cause
Remedy
10
Air brackets not set parallel
Adjust air brackets according to scale
11
Gap between sheets is too narrow
Increase sheet gap via BASIC menu
12
Pump not switched on
Switch on pump
13
Suction drum is loose
Tighten suction drum (3 Allen screws)
14
Timing belt pulley is loose
Tighten timing belt pulley
15
Sheets are not fed at right angles
Align angle of register rail
16
Sheets are not cut at right angles
Adapt fold plate stop to the sheet by
adjusting the knurled screw
17
Fold plate stop not set correctly
Readjust fold length via the BASIC menu
18
Change of fold speed
Set regular speed via the BASIC menu
19
Distance between ejector rollers
Increase distance via the BASIC menu
and hold-down rollers too short
20
Ejector rollers on knife shafts are
Arrange ejector rollers evenly across
not distributed evenly across
the paper width
paper width
21
Ejector rollers worn
Replace rollers
22
Paper jam, safety system has
Clear jam, switch the machine off
switched off the machine
and then on again