Possible malfunctions and their remedies – MBM Corporation 352SA automatic air suction folder with Register System User Manual
Page 64

Operator's Manual multimaster CAS 35 PBA
Mathias Bäuerle GmbH
65
16. Possible Malfunctions and their Remedies
Error:
see no.
Intermittent and irregular paper feed
1
2
Creasing
3
4
5
6
7
Several sheets are fed together
8
9
10
Sheets are not transported up to fold plate stop
11
Feeder does not start
12
13
14
Skewed folds
15
Points
16
Fold variations
17
18
Paper jam in delivery section
19
20
21
Folder does not start
22
No.
Possible Cause
Remedy
1
Air brackets are set too narrow
Set with a little more side play
2
Vacuum too low
Increase vacuum by opening the corres-
ponding valve a little more
3
Speed too high
Reduce speed
4
Sheets are not fed at right angles
Align register rail
5
Pressure of first pair of fold rollers
Have pressure and parallel alignment
too strong or uneven
set by service technician
6
Too many steel balls in ball cage
Use more plastic balls
of register rail
7
Insufficient guidance by balls
Shift ball cages
8
Front paper stop is not set to the
Change height by means of setting screw
correct height
9
Vacuum too strong
Reduce vaccum