Care and cleaning, Charcoal filter replacement, Cooktop/night light replacement – Maytag MMV4205AAQ User Manual
Page 24: Oven light replacement, Caution
24
Care and Cleaning
CHARCOAL FILTER
REPLACEMENT
If your oven is vented inside, the
charcoal filter should be replaced
every 6 to 12 months, and more often
if necessary. The charcoal filter cannot
be cleaned. To order a new charcoal
filter, contact the Parts Department at
your nearest Authorized Service Center
or call 1-800-688-9900 (inside U.S.A)
or 1-800-688-2002 (Canada).
Order Charcoal Filter kit #: MVHRK3.
1. Unplug the oven or turn off power at
the main power supply.
2. Remove the two vent grille mounting
screws. (2 screws)
3. Push the right side lower part of the
charcoal filter.
4. Remove old filter.
5. Slide a new charcoal filter into place.
The filter should rest at the angle
shown.
6. Slide the bottom of the grille into
place. Push the top until it snaps into
place. Replace the mounting screws.
Turn the power back on at the main
power supply and set the clock.
COOKTOP/NIGHT LIGHT
REPLACEMENT
1. Unplug the oven or turn off power at
the main power supply.
2. Remove the bulb cover mounting
screws.
3. Replace bulb(s) with 30 or 40 watt
appliance bulb(s).
4. Replace bulb cover, and mounting
screws.
5. Turn the power back on at the main
power supply.
OVEN LIGHT
REPLACEMENT
1. Unplug oven or turn off power at the
main power supply.
2. Remove the vent cover mounting
screws. (2 screws)
3. Tip the cover forward, then lift out to
remove.
4. Push the hook.
5. Lift up the bulb holder.
6. Replace bulb with a 30 or 40 watt
appliance bulb.
7. Replace the bulb holder.
8. Slide the bottom of the vent cover
into place. Push the top until it snaps
into place. Replace the mounting
screws. Turn the power back on at
the main power supply.
Hook
To avoid personal injury or
property damage, wear gloves
when replacing light bulb.
CAUTION
To avoid risk of personal injury or
property damage, do not operate
oven hood without filters in place.